beautypg.com

3 connecting to local switch client through a pvc, Connecting to local switch client through a pvc -4 – Cabletron Systems Smart 04-0053-01 User Manual

Page 70

background image

5-4 SmartSwitch ATM User Guide

PVC Connections

Virtual Ports and Static Connections

5.

Connect the workstations to their respective ports.

6.

Configure the workstations for the same subnet and VPCI/VCI pair = 0/101.

The broadcasting workstation on port

7a1

can send traffic to the receiving workstations on ports

7a2

,

7a3

, and

7a4

.

5.1.3

Connecting to Local Switch Client Through a PVC

All PVC connections to an ATM SmartSwitch local client use the CPU port. On a SmartSwitch 6500, this port is either

7B4

or

8B4

depending on the slot in which the master TSM/CPU module resides. Because of the SmartSwitch 6500’s

redundancy capability, the CPU port should always be designated as

CPU

. Using

CPU

assures that the PVC connects to

the active CPU in the event of fail-over. On all other SmartSwitch ATM switches (2500, 6A000, or 9A100), the CPU
port is

B4

, however, as with the SmartSwitch 6500, the value

CPU

can also be used.

Follow these instructions to connect an end node to an ATM SmartSwitch’s local client through a point-to-point PVC.

1.

Use

add pvc

to create the PVC.

SmartSwitch # add pvc

ConnType(PTP) :

Port-1-Number() : 7a1

Port-1-VPCI() : 0

Port-1-VCI() : 100

Port-2-Number() : cpu

— The CPU port

Port-2-VPCI() : 0

Port-2-VCI() : 101

Port1-to-Port2TrafficDescriptorIndex() : 2

Port2-to-Port1TrafficDescriptorIndex() : 2

SmartSwitch #

2.

Use

add ipatmclient

to create an IP over ATM local client.

SmartSwitch # add ipatmclient

ClientNumber(0) : 2

— Set client number 2

ServerType(None) : local

— ARP server is on the switch

ServerAddress() :

IPAddress() : 100.1.1.0

NetMask(255.0.0.0) :

MTU(9180) :

SmartSwitch #

3.

Use

add ipatmpvc

to associate the end node’s IP address with the PVC.

SmartSwitch # add ipatmpvc

ClientNumber(0) : 2

— Specify local client number

DestinationVPCI(0) :

DestinationVCI(33) : 101

—VCI to CPU port was specified as 101

SmartSwitch #

4.

Connect the end node to port

7a1

of the ATM SmartSwitch.