AVer MOB1304 User Manual
Page 48
42
OSD MENU
Description
FAN ON
FAN OFF
TEMPERATURE SETUP
TEMP. TYPE
ALARM THRESHOLD
050
040
060/005
HDD STOP
070/005
RESET TO DEFAULT
C
ALARM THRESHOLD
Set the temperature high/low limit (0~100°C/55 ~ 95°C) to prevent
DVR unit overheating/overcooling. When DVR unit temperature
reaches the high/low limit, the system will show the warning message
or send out alarm if the alarm is connected and set.
HDD STOP
Set a specific temperature high/low limit (70 ~100°C /55 ~ 95°C) for
HDD shutdown. When the hard disk temperature reaches the
temperature limit, the HDD will shutdown.
RESET TO DEFAULT
Set all configurations back to factory default.
EVENT SETUP
ALARM SETTING
SENSOR SETTING
MOTION DETECTION
TEMPERATURE
SHOCK DETECTION
VOLTAGE
SHOCK DETECTION SETUP
Set the sensitivity level for vehicle slope detection.
SHOCK DETECTION SETUP
SENSITIVITY
RESET TO DEFAULT
6
SENSTIVITY
Set the sensitivity level of the shock detection.
RESET TO DEFAULT
Set all configurations back to factory default.
EVENT SETUP
ALARM SETTING
SENSOR SETTING
MOTION DETECTION
TEMPERATURE
SHOCK DETECTION
VOLTAGE
VOLTAGE SETUP
RTC(3V) DETECTION
SHOUTDOWN SYSTEM
VOLTAGE SETUP
12V DETECTION
12V DETECTION
Enable/disable voltage limit for total power supply of DVR system.
RTC(3V) DETECTION
Enable/disable voltage limit for RTC (real time clock).
SHOUTDOWN SYSTEM
Enable/disable to shutdown system when the voltage threshold
reaches the limit.