AVer MOB1304 User Manual
Page 46
40
OSD MENU
Description
ALARM CONTINUOUSLY
ALARM PERIOD
ALARM TYPE
SELECT / DESELECT ALL
SENSOR
RECORD
MOTION DETECTION
TEMPERATURE
VIDEO LOSS
VOLTAGE
SHOCK DETECTION
REMOTE TRIGGER
HDD FAIL
FAN FAIL
005 SEC
ALARM SETUP
1
2
3
4
VIDEO LOSS
Select the channel that will send out the alarm when video is lost.
HDD FAIL
Enable/disable to send out alarm when hard disk is failed.
FAN FAIL
Enable/disable to send out alarm when fan is broken or doesn
‟t
start/stop when temperature is over/lower the limit.
EVENT SETUP
ALARM SETTING
SENSOR SETTING
MOTION DETECTION
TEMPERATURE
SHOCK DETECTION
VOLTAGE
SENSOR
Customize the initial state of the attached sensor.
ENABLE
Active/deactivate the sensor.
TYPE
Select the state of the sensor.
-
NO: Indicates that the initial state of the sensor is normal open.
Video recording initiates when there is a changes in the sensor
state
-
NC: Indicates that the initial state of the sensor is normal close.
Video recording initiates when there is a changes in the sensor
state
SENSOR SETUP
TYPE
ENABLE
SENSOR1 SENSOR2 SENSOR3 SENSOR4
NO
NO
NO
NO