CHAPTER 3: INSTALLATION
3-4
EMM-E6 User’s Guide
Switch definitions are as follows:
• Switch 1 - Cabletron Systems use only.
• Switch 2 - Cabletron Systems use only.
• Switch 3 - For manufacturing use only. Keep in
OFF
position.
• Switch 4 - MIMREV (Management Interface Module Revision).
This switch remains in the
OFF
position for normal operation. Only
if you are using THN-MIM part numbers 9000043-05 and below in
your MMAC-FNB should the switch be in the ON position.
• Switch 5 - Baud Rate Default. Allows you to set the Console port’s
baud rate. The OFF position sets the baud rate to 9600. The ON
position sets the baud rate to 2400.
•
Switch 6 - Forced Download. Changing the state of this switch
(i.e., moving the switch from one position to another) clears
download information from NVRAM and forces the EMM-E6 to
download an image file from the station acting as the EMM-E6’s
BOOTP server.
Changes to switch positions only activate their associated
functions after the EMM-E6 is reset.
NOTE
Do NOT change the state of Switch 6 unless you:
-
have a station acting as a BOOTP server, and
that station contains the EMM-E6 image file.
-
intend to set up a station to act as a BOOTP
server for the EMM-E6.
NOTE
CH1Book Page 4 Wednesday, March 20, 1996 7:48 AM