beautypg.com

A.3 com 1 port, A.4 com 2 port, A.5 environmental requirements – Cabletron Systems EMM-E6 Ethernet User Manual

Page 165

background image

EMM-E6 User’s Guide

A-3

A.3

COM 1 PORT

Type: Standard RJ45 port

Pin 1

Transmit Data (XMT)

From COM 1 port

2

Data Set Ready (DSR)

To COM 1 port

3

Not used

4

Receive Data (RCV)

To COM 1 port

5

Signal Ground (GND)

6

Data Terminal Ready (DTR)

From COM 1 port

7

Not used

8

Not used

A.4

COM 2 PORT

Type:

Standard RJ45 port

Pin 1

Transmit Data (XMT)

From COM 2 port

2

Data Set Ready (DSR)

To COM 2 port

3

Not used

4

Receive Data (RCV)

To COM 2 port

5

Signal Ground (GND)

6

Data Terminal Ready (DTR)

From COM 2 port

7

Not used

8

Not used

A.5

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:

+5

°

to +40

°

C (+41

°

to +104

°

F)

Non-operating Temperature:

-30

°

to +90

°

C (-22

°

to +194

°

F)

Operating Humidity:

5 to 95% (non-condensing)

CH1Book Page 3 Wednesday, March 20, 1996 7:48 AM