Qmark CWH3000 Series - Commercial Fan-Forced Wall Heaters User Manual
Whb3000 series, Save these instructions, Installation, operation & maintenance instructions
WHB3000 Series
Fan Forced
Electric Wall Heaters
WHEN USING ELECTRIC APPLIANCES, BASIC
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND
INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture, pillows, bedding, papers, clothes, etc. and curtains at
least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a
reputable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power to
heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock, fire, or
damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust in
any manner.
9. A heater has hot and arcing or sparking parts inside. Do not use
it in areas where gasoline, paint, or flammable liquids are used
or stored.
10. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.
11. This heater is intended for comfort heating applications and not
intended for use in special environments. Do not use in damp
or wet locations such as marine or greenhouse or in areas
where corrosive or chemical agents are present.
12. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
13. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
WARNING
IMPORTANT INSTRUCTIONS
Installation, Operation & Maintenance Instructions
PPD41511
09/14
5200-11209-000
Table 1. Specifications
Min.
Supply
Model
Wire
Number
Volts
Phase
Watts*
Amps
Gauge
WHB3150FC
120
1
1500
12.5
12
WHB3180FC
120
1
1800
15.0
12
WHB3404FC*
240/208
1
4000/3000 16.7/14.5
10
2000/1500
8.3/7.2
12
WHB3407FC*
277/240
1
4000/3000 14.5/12.5
12
2000/1500
7.2/6.3
12
WHB3307FC*
277
1
3000/1500 10.8/5.4
14
WHB3408FC*
208
1
4000/2000 19.2/9.6
10
WHB34083FC
208
3
4000
11.1
14
WHB34043FC
240
3
4000
9.7
14
WHB3504FC
240/208
1
4800/3600 20.0/17.3
10
WHB3507FC
277/240
1
4800/3600
17.3/15
10
WHB3508FC
208
1
4800
23.1
10
*NOTE: Factory wired for higher wattage, field convertible to half wattage.
Min.
Supply
Model
Wire
Number
Volts
Phase
Watts*
Amps
Gauge
WHB35083FC
208
3
4800
13.4
12
WHB35043FC
240
3
4800
11.6
14
WHB3203FC
347
1
2000
5.8
14
WHB3206FC
600
1
2000
3.3
14
WHB3153FC
347
1
1500
4.3
14
WHB3156FC
600
1
1500
2.5
14
WHB3303FC
347
1
3000
8.6
14
WHB3306FC
600
1
3000
5
14
WHB3403FC
347
1
4000
11.5
14
WHB3406FC
600
1
4000
6.7
14
WHB3503FC
347
1
4800
13.8
12
WHB3506FC
600
1
4800
8
14
*NOTE: Factory wired for higher wattage, field convertible to half wattage.
Conforms to ANSI/UL2021
and CSA C22.2, No. 56
Conforms to ANSI/UL2021
and CSA C22.2, No. 56
15-3/4”
(400mm)
19-5/16”
(490mm)
14-5/16”
(363mm)
3-3/4”
(95mm)
1-1/4”
(32mm)
18-1/4”
(464mm)
15-3/4”
(400mm)
19-5/16”
(490mm)
14-5/16”
(363mm)
3-3/4”
(95mm)
1-1/4”
(32mm)
18-1/4”
(464mm)