WHB3000 Series

Fan Forced

Electric Wall Heaters

WHEN USING ELECTRIC APPLIANCES, BASIC
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND
INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare

skin touch hot surfaces. Keep combustible materials, such as

furniture, pillows, bedding, papers, clothes, etc. and curtains at

least 3 feet (0.9 m) from the front of the heater.

3. Extreme caution is necessary when any heater is used by or

near children or invalids and whenever the heater is left

operating and unattended.

4. Do not operate any heater after it malfunctions. Disconnect

power at service panel and have heater inspected by a

reputable electrician before using.

5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power to

heater circuit at main disconnect panel.

7. Do not insert or allow foreign objects to enter any ventilation or

exhaust opening as this may cause an electric shock, fire, or

damage to the heater.

8. To prevent a possible fire, do not block air intake or exhaust in

any manner.

9. A heater has hot and arcing or sparking parts inside. Do not use

it in areas where gasoline, paint, or flammable liquids are used

or stored.

10. Use this heater only as described in this manual. Any other use

not recommended by the manufacturer may cause fire, electric

shock, or injury to persons.

11. This heater is intended for comfort heating applications and not

intended for use in special environments. Do not use in damp

or wet locations such as marine or greenhouse or in areas

where corrosive or chemical agents are present.

12. When installing, see INSTALLATION INSTRUCTIONS for

additional warnings and precautions.

13. For safe and efficient operation, and to extend the life of your

heater, keep your heater clean - See MAINTENANCE

INSTRUCTIONS.

SAVE THESE INSTRUCTIONS

!

WARNING

IMPORTANT INSTRUCTIONS

Installation, Operation & Maintenance Instructions

PPD41511

09/14

5200-11209-000

Table 1. Specifications

Min.

Supply

Model

Wire

Number

Volts

Phase

Watts*

Amps

Gauge

WHB3150FC

120

1

1500

12.5

12

WHB3180FC

120

1

1800

15.0

12

WHB3404FC*

240/208

1

4000/3000 16.7/14.5

10

2000/1500

8.3/7.2

12

WHB3407FC*

277/240

1

4000/3000 14.5/12.5

12

2000/1500

7.2/6.3

12

WHB3307FC*

277

1

3000/1500 10.8/5.4

14

WHB3408FC*

208

1

4000/2000 19.2/9.6

10

WHB34083FC

208

3

4000

11.1

14

WHB34043FC

240

3

4000

9.7

14

WHB3504FC

240/208

1

4800/3600 20.0/17.3

10

WHB3507FC

277/240

1

4800/3600

17.3/15

10

WHB3508FC

208

1

4800

23.1

10

*NOTE: Factory wired for higher wattage, field convertible to half wattage.

Min.

Supply

Model

Wire

Number

Volts

Phase

Watts*

Amps

Gauge

WHB35083FC

208

3

4800

13.4

12

WHB35043FC

240

3

4800

11.6

14

WHB3203FC

347

1

2000

5.8

14

WHB3206FC

600

1

2000

3.3

14

WHB3153FC

347

1

1500

4.3

14

WHB3156FC

600

1

1500

2.5

14

WHB3303FC

347

1

3000

8.6

14

WHB3306FC

600

1

3000

5

14

WHB3403FC

347

1

4000

11.5

14

WHB3406FC

600

1

4000

6.7

14

WHB3503FC

347

1

4800

13.8

12

WHB3506FC

600

1

4800

8

14

*NOTE: Factory wired for higher wattage, field convertible to half wattage.

Conforms to ANSI/UL2021

and CSA C22.2, No. 56

Conforms to ANSI/UL2021

and CSA C22.2, No. 56

15-3/4”

(400mm)

19-5/16”

(490mm)

14-5/16”

(363mm)

3-3/4”

(95mm)

1-1/4”

(32mm)

18-1/4”

(464mm)

15-3/4”

(400mm)

19-5/16”

(490mm)

14-5/16”

(363mm)

3-3/4”

(95mm)

1-1/4”

(32mm)

18-1/4”

(464mm)