beautypg.com

Qmark COS-E Series - Residential Fan-Forced Zonal Wall Heaters User Manual

Cos-e series, Save these instructions, Installation, operation & maintenance instructions

background image

WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:

1.

Read all instructions before installing or using this heater.

2. This heater is hot when in use. To avoid burns, do not let

bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.

3. Extreme caution is necessary when any heater is used by or

near children or invalids and whenever the heater is left
operating and unattended.

4. Do not operate any heater after it malfunctions. Disconnect

power at service panel and have heater inspected by a rep-
utable electrician before using.

5. Do not use outdoors.

6. To disconnect heater, turn controls to off, and turn off power

to heater circuit at main disconnect panel.

7.

Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.

8. To prevent a possible fire, do not block air intake or exhaust

in any manner.

9. A heater has hot and arcing or sparking parts inside. Do not

use it in areas where gasoline, paint, or flammable liquids
are used or stored.

10. Use this heater only as described in this manual. Any other

use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.

11. This heater is provided with a an automatic safety limit con-

trol that shuts the heater off should it overheat. If you find
the heater off, inspect for any objects on or adjacent to the
heater that may have blocked the airflow or otherwise
caused high temperatures to have occurred and remove any
objects that may have caused the overheating. Refer to the
Maintenance Instructions section of this manual for how to
reset this safety control.

12. This heater is intended for comfort heating applications and

not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.

13. When installing, see INSTALLATION INSTRUCTIONS for

additional warnings and precautions.

14. For safe and efficient operation, and to extend the life of your

heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.

SAVE THESE INSTRUCTIONS

!

Installation, Operation & Maintenance Instructions

WARNING

ECR 40234

08/14

5200-11217-002

IMPORTANT INSTRUCTIONS

COS-E Series

Fan-Forced Wall Heaters

MODEL

MODEL

VOLTS

WATTS/AMPS

WATTS/AMPS*

CZ1512T

CZ1512-IF

120

1500W/12.5A

750W/6.3A

CZ1012T

CZ1012-IF

120

1000W/8.4A

750W/4.2A

CZ1548T

CZ1548-IF

240

1500W/6.3A

750W/3.1A

208

1125W/5.4A

563W/2.7A

CZ1048T

CZ1048-IF

240

1000W/6.3A

500W/2.1A

208

750W/3.6A

375W/1.8A

CZ2048T

CZ2048-IF

240

2000W/8.3A

1000W/4.2A

208

1500W/7.2A

750W/3.6A

Table 1. Specifications

* Factory wired for full wattage, field convertible to half wattage.
*-IF Models provided without back box or thermostat. Model CZBB Back-box and Model CZTDP thermostat kit sold separately.

CLIP-N-FIT

®

FEATURE

Patented CLIP-N-FIT

®

feature (US Patented

#6,172,343) allows installer to pick a
wattage onsite. Factory wired for full
wattage, easily field adjustable for half
wattage. Half wattage option is permanent
change complying with many local electrical
code requirements.

Conforms to ANSI/UL2021 and

CSA C22.2, No. 46