Qmark Mechanical Artisan - Heavy-Duty Architectural Wall Heater User Manual
Mcarwh series, Save these instructions, Installation, operation & maintenance instructions
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:
1.
Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a rep-
utable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to OFF, and turn OFF
power to heater circuit at main disconnect panel.
7.
Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is provided with a red alarm light that will illumi-
nate only if the heater has turned off as a result of over-
heating. Should the sensor register an overheat condition,
the heater will stop generating heat, the fan will turn off, and
the red alarm light will turn ON. DO NOT OPERATE THE
HEATER WITH THE ALARM LIGHT ILLUMINATED. See
“TO RESET MANUAL RESET LIMIT” in OPERATING
INSTRUCTION section.
12. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
13. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
14. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
PPD 39696
4/14
5200-11204-000
IMPORTANT INSTRUCTIONS
MCARWH Series
Mechanical Artisan
Heavy-Duty Architectural
Wall Heater
MIN. SUPPLY
MODEL
VOLTS
PHASE
WATTS
AMPS
WIRE GAUGE
MCARWH1802
120
1
1800
15
12
MCARWH4808
208
1
4000 / 2000
19.2 / 9.6
10
MCARWH4804
240
1
4800 / 2400
20.0 / 10.0
10
MCARWH4807
277
1
4800 / 2400
17.3 / 8.7
12
Table 1. Specifications
NOTE: The model numbers shown are Northern White color. Add suffix to the model number for the following colors:
AL = Aluminum, BZ = Bronze, W = Navajo White.