beautypg.com

Power on the circuit breaker, Step 4, Feed a2 – Cisco XR 12410 User Manual

Page 130

background image

Chapter 3 Installing the Cisco XR 12410 Router

Connecting Power to the Router

3-48

Cisco XR 12410 and Cisco XR 12810 Router Installation Guide

OL-17441-01

Figure 3-31

Connecting the DC Power Cables—2800 W PDU

Step 3

Replace the clear plastic safety covers over the PDUs.

Step 4

Power on the circuit breaker.

Feed A2

-48/-60V
-40A MAX (2x)

+

+

-48/-60V
-40A MAX (2x)

+

+

129277

Ground

– 48/60V RTN

(+)

– 48/60V RTN

(+)

– 48/60V (–)

– 48/60V (–)

Feed A1