beautypg.com

Dell PowerVault DL2000 User Manual

Page 33

background image

About Your System

33

Table 1-7.

System Messages

Message

Causes

Corrective Actions

Alert! Redundant

memory disabled!

Memory

configuration does

not support

redundant memory.

Installed memory modules
are not the same type and
size; faulty memory
module(s).

Ensure that all memory
modules are of the same
type and size and that they
are properly installed. If the
problem persists, see
"Troubleshooting System
Memory" on page 142.

Attempting to

update Remote

Configuration.

Please wait...

Remote Configuration
request has been detected
and is being processed.

Wait until the process is
complete.

BIOS Update

Attempt Failed!

Remote BIOS update
attempt failed.

Retry the BIOS update. If
problem persists, see
"Getting Help" on page 167.

Caution! NVRAM_CLR

jumper is

installed on

system board.

NVRAM_CLR jumper is
installed. CMOS has been
cleared.

Remove NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.

CPUs with

different cache

sizes detected!

Microprocessors with
different cache sizes are
installed.

Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on
page 105.

Decreasing

available memory

Faulty or improperly
installed memory modules.

See "Troubleshooting
System Memory" on
page 142.

Book.book Page 33 Monday, September 14, 2009 12:57 PM