Dell PowerVault DL2000 User Manual
Page 26
26
About Your System
E1712
PCI SERR B##
D## F##
PCI SERR Slot
#
The system BIOS has
reported a PCI system
error on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCI system
error on a component that
resides in the specified
slot.
Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.
E1714
Unknown Err
The system BIOS has
determined that there has
been an error in the
system, but is unable to
determine its origin.
See "Getting Help" on
page 167.
E171F
PCIE Fatal
Err B## D##
F##
PCIE Fatal
Err Slot #
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.
Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.
E1810
HDD ## Fault
The SAS subsystem has
determined that hard drive
## has experienced a
fault.
See "Troubleshooting a
Hard Drive" on page 146.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
Book.book Page 26 Monday, September 14, 2009 12:57 PM