beautypg.com

Dell PowerEdge RAID Controller 6E User Manual

Page 117

background image

Troubleshooting

117

Invalid SAS topology

detected. Please check your

cable configurations, repair

the problem, and restart your

system.

The SAS cables for your system are
improperly connected. Check the cable
connections and fix problems if any.
Restart the system.

Multibit ECC errors were

detected on the RAID

controller. If you continue,

data corruption can occur.

Contact technical support to

resolve this issue. Press 'X'

to continue or else power off

the system, replace the

controller and reboot.

This error is specific to the PERC 6/i
controller.

Multi-bit ECC errors (MBE) occur in the
memory and can corrupt cached data and
discard it.

CAUTION:

MBE errors are serious, as

they cause data corruption and data loss.
In case of MBE errors, contact Dell
Technical Support.

NOTE:

A similar message displays when

multiple single-bit ECC errors are detected
on the controller during bootup.

Multibit ECC errors were

detected on the RAID

controller.The DIMM on the

controller needs

replacement. If you continue,

data corruption can occur.

Press 'X' to continue or else

power off the system, replace

the DIMM module, and reboot.

If you have replaced the DIMM

please press 'X' to continue.

This error is specific to the PERC 6/E
controller.

Multi-bit ECC errors (MBE) occur in the
memory and can corrupt cached data and
discard it.

Table 7-1.

BIOS Errors and Warnings (continued)

Message

Meaning

Dell_PERC6.2_UG.book Page 117 Wednesday, June 24, 2009 6:08 PM