Replace member errors – Dell PowerEdge RAID Controller 6E User Manual
Page 126

126
Troubleshooting
Replace Member Errors
Table 7-7 describes issues related to the Replace Member feature.
NOTE:
For more information about the Replace Member features, see "Using
Replace Member and Revertible Hot Spares" on page 37.
A SMART error
occurs during a
Consistency Check
(CC)
Specify how the CC operation must perform when a SMART
error is encountered.
There are two settings, Yes and No. No is the default setting
and allows CC to continue when the first error is encountered.
The Yes setting halts CC when the first error is encountered.
Events are generated in the Event Log when errors are
encountered during CC.
Table 7-7.
Replace Member Operation Errors
Problem
Suggested Solution
The source drive fails
during the Replace
Member operation.
If the source data is available from other drives in the virtual
disk, the rebuild begins automatically on the target drive, using
the data from the other drives.
Target drive fails
If the target drive fails, the Replace Member operation aborts.
Other drives fail
If the target drive fails and the Replace Member operation
aborts but the source data is still available, then the Replace
Member operation continues as Replace Member.
Table 7-6.
SMART Errors (continued)
Problem
Suggested Solution
Dell_PERC6.2_UG.book Page 126 Wednesday, June 24, 2009 6:08 PM