beautypg.com

Dell PowerEdge RAID Controller 6E User Manual

Page 116

background image

116

Troubleshooting

Foreign configuration(s)

found on adapter. Press any

key to continue, or ’C’ to

load the configuration

utility or ’F’ to import

foreign configuration(s) and

continue.

When a controller firmware detects a
physical disk with existing foreign
metadata, it flags the physical disk as

foreign and generates an alert indicating
that a foreign disk was detected.

Press at this prompt to import the
configuration (if all member drives of the
virtual disk are present) without loading
the BIOS configuration utility. Or, press
to enter the BIOS configuration
utility and either import or clear the
foreign configuration.

The foreign configuration message is
always present during POST but no
foreign configurations are present in the
foreign view page in CTRL+R. All virtual
disks are in an optimal state.

Clear the foreign configuration using
CTRL+R or Dell OpenManage™ Server
Administrator Storage Management.

CAUTION:

The physical disk goes to

Ready state when you clear the foreign
configuration and this may lead to
data loss.

If you insert a physical disk that was
previously a member of a virtual disk in
the system, and that disk’s previous
location has been taken by a replacement
disk through a rebuild, you must manually
remove the foreign configuration flag of
the newly inserted disk.

Previous configuration(s)

cleared or missing. Importing

configuration created on

XX/XX XX.XX. Press any key to

continue, or ’C’ to load the

configuration utility.

The message indicates that the controller
and physical disks have different
configurations. You can use the BIOS
Configuration Utility to clear the foreign
configuration.

Table 7-1.

BIOS Errors and Warnings (continued)

Message

Meaning

Dell_PERC6.2_UG.book Page 116 Wednesday, June 24, 2009 6:08 PM