beautypg.com

Dell PowerEdge RAID Controller 5i User Manual

Page 82

background image

80

Troubleshooting

Table 6-8 lists the critical and warning events, severity levels of the events, and audible codes.

NOTE:

If the PERC 5/E alarm was already beeping due to a previous failure and a new virtual disk is created on the

same controller, then the previous alarm will be silenced. This is expected behavior.

Table 6-8.

Audible Alarm Descriptions

Description

Severity

Audible Code

Controller alarm enabled

Normal

N/A

Virtual disk failed

Critical

3 seconds on, 1 second off

Virtual disk degraded

Warning

1 second on, 1 second off

Global hot spare failed

Warning

1 second on, 1 second off

Dedicated hot spare failed

Warning

1 second on, 1 second off

Physical disk failed

Critical

1 second on, 1 second off

Rebuild completed on physical disk

Normal

1 second on, 3 seconds off

Rebuild failed on physical disk

Warning

1 second on, 1 second off

Physical disk offline

Critical

1 second on, 1 second off

Dell_PERC5_UG.book Page 80 Tuesday, February 13, 2007 6:02 PM