Dell PowerEdge 2450 User Manual
Page 27

support.dell.com
Messages and Codes
3-11
1-3-2
No memory installed
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
1-3-3
Chip or data line failure in the
first 64 KB of main memory
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
1-3-4
Odd/even logic failure in the first
64 KB of main memory
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
1-4-1
Address line failure in the first
64 KB of main memory
1-4-2
Parity failure in the first 64 KB of
main memory
2-1-1
through
2-4-4
Bit failure in the first 64 KB of
main memory
3-1-1
Slave DMA-register failure
Replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
3-1-2
Master DMA-register failure
3-1-3
Master interrupt-mask register
failure
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and
Acronyms."