Dell PowerEdge 2450 User Manual
Page 21
support.dell.com
Messages and Codes
3-5
$ (+"
Microprocessor not supported by
system
Install a correct version of the
microprocessor in the specified
microprocessor connector.
$ 23)
4
System detected and corrected a
resource conflict when system
resources were allocated using
the Resource Configuration Utility
No action is required.
$5*
Expansion card improperly
installed or faulty
Reinstall the expansion cards (see
Chapter 8, “Installing System
Board Options”). If the problem
persists, replace the expansion
card.
6
Keyboard cable connector loose
or improperly connected, defec-
tive keyboard, or defective
keyboard/mouse controller
(defective system board)
Check the keyboard cable con-
nection. Replace the keyboard. If
the problem persists, replace the
system board. See Chapter 11,
“Getting Help,” for instructions
on obtaining technical assistance.
6
Defective keyboard/mouse con-
troller (defective system board)
Replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
6
6
Keyboard cable connector loose
or improperly connected, defec-
tive keyboard, or defective
keyboard/mouse controller
(defective system board)
Check the keyboard cable con-
nection. Replace the keyboard. If
the problem persists, replace the
system board. See Chapter 11,
“Getting Help,” for instructions
on obtaining technical assistance.
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and Acronyms."