Dell PowerEdge 2450 User Manual
Page 23
support.dell.com
Messages and Codes
3-7
2
Faulty diskette, diskette/tape
drive subsystem, or hard-disk
drive subsystem
Replace the diskette or hard-disk
drive. If the problem persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
2
No operating system on diskette
Use a bootable diskette.
+
No microprocessor or terminator
card installed in secondary micro-
processor connector
Install a terminator card or micro-
processor in the secondary
microprocessor connector. See
Chapter 8, “Installing System
Board Options,” for instructions.
)
)7
Faulty diskette, diskette/tape
drive subsystem, or hard-disk
drive subsystem (defective sys-
tem board)
Replace the diskette or hard-disk
drive. If the problem persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
)
Improperly connected diskette/
tape drive, hard-disk drive, or
power cable
Check that the diskette drive/
CD-ROM drive unit is seated
properly against the interposer
board on the peripheral cage. See
Chapter 9, “Installing a Drive in
the Peripheral Bay.” Reinstall the
hard-disk drive. Check the inter-
face cable and power cable
connections to the backplane
board. See Chapter 10, “Installing
Hard-Disk Drives.”
)*! 8
Expansion card improperly
installed or faulty
Reinstall the expansion cards (see
Chapter 8, “Installing System
Board Options”). If the problem
persists, replace the expansion
card.
Defective sectors on diskette or
hard-disk drive
Replace the diskette or hard-disk
drive.
Defective sectors on diskette or
hard-disk drive
Replace the diskette or hard-disk
drive.
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and Acronyms."