Dell PowerEdge 2450 User Manual
Page 22
3-6
Dell PowerEdge 2450 Systems Installation and Troubleshooting Guide
4
,
4
5
4
,5
4
Faulty or improperly seated
DIMMs or defective system
board
Remove and reseat the DIMMs.
If the problem persists, replace
the DIMMs. See Chapter 11,
“Getting Help,” for instructions
on obtaining technical assistance.
Faulty application
Restart the application.
Improperly seated or faulty
DIMMs
Remove and reseat the DIMMs.
If the problem persists, replace
the DIMMs. See Chapter 11,
“Getting Help,” for instructions
on obtaining technical assistance.
POST memory test terminated by
pressing the spacebar
No action is required.
2
Faulty diskette, diskette/tape
drive subsystem, hard-disk drive,
hard-disk drive subsystem, or no
boot disk in drive A
Replace the diskette or hard-disk
drive. If the problem persists,
replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
2!
Incorrect configuration settings in
System Setup program, or no
operating system on hard-disk
drive
Check the hard-disk drive configu-
ration settings in the System
Setup program. See Chapter 4,
"Using the System Setup Pro-
gram," in the User's Guide for
instructions.
2
Defective system board
Replace the system board. See
Chapter 11, “Getting Help,” for
instructions on obtaining technical
assistance.
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and Acronyms."