beautypg.com

Baumer TA1220 User Manual

Page 22

background image

TA1220

22

www.baumer.com

3.2 Inputs and outputs
Signal input

Specification

PNP

High level >2.6 V

Low level <2.4 V

Input resistance 1.5 kΩ

NPN

High level >2.6 V

Low level <2.4 V

Input resistance 3.9 kΩ

TTL

High level >2.6 V

Low level <2.4 V

NAMUR

Ion <1 mA, Ioff >3 mA

Input resistance 1.5 kΩ

Magnetic sensor

Vin >30 mVeff at 60 Hz

Vin >300 mVeff at 6 kHz

Contact

Input resistance 3.9 kΩ

Voltage 10...600 VAC

Measuring the frequency of the

voltage

Relay outputs (SET 1, SET 2)

Switching voltage max.

250 VAC / 110 VDC

Switching current max.

1 A

Switching performance max.

150 VA / 30 W

3.3 Voltage supply connection
There are several options for operation supply. Power supply must

be fed in via the recommended external fuse.

Operating voltage

External protection

85...265 VAC, (50/60 Hz) and 100...300 VDC

M 100 mA

21...53 VAC, (50/60 Hz) and 10.5...70 VDC

M 1 A