Connect the 120 volt wires – Edge Lighting 600W/12V Remote Recessed Transformer User Manual
Page 3

T2
T3
T4
T1
COM 1
COM 2
3
C
Connect the 120 Volt Wires
1: Install the 120 Volt power wires to the transformer.
2: Insert the hot power wire inline with the black transformer
wire into the 120 Volt terminal block and tighten the screw
firmly.
3: Insert the neutral power wire inline with the white
transformer wire into the 120 Volt terminal block and tighten
the screw firmly.
4: Ground the transformer housing in accordance with local
electrical codes.
D
5: After installing the entire low voltage system, if the lamps
have low intensity, then measure the voltage at the fixture
closest to the power feed contacts with a voltmeter. The
system must be at least 80% loaded and the voltmeter
should read between 11V-12V ~AC. If the voltage does not
fall in this range, call Edge Lighting "Technical Support" at
773-770-1195.
6: After operating the system for a few minutes, on the low
voltage side, all electrical connection points should be no
more than warm to the touch. If a connection is hot to the
touch, retighten the connection and check to ensure that
the temperature decreases.
7: Replace the transformer cover and tighten the four Phillips
screws on the front of the transformer.
120 VOLT
TERMINAL BLOCK
HOT POWER
WIRE
NEUTRAL POWER
WIRE
4
1
2
3
COVER
PHILLIPS SCREW
7
7
7
7