7.7.7 BT Sensor Dome - Connection (‘TERRATEST 5000 BLU’ ONLY)
7.7.7.1 Stand-by Time
The testing computer can be operated in two measuring modes: ‘SINGLE
MEASURING MODE’ and ‘CONTINUOUS MEASURING MODE’. If several
tests shall be performed in a limited period of time, it is useful to set the
testing computer to ‘CONTINUOUS MEASURING MODE’. If set to ‘SINGLE
MEASURING MODE’ (default setting), the testing computer must be
operated between the single tests by pressing the appropriate buttons on the
testing computer. If set to ‘CONTINUOUS MEASRUING MODE’, the next
test will be started if the drop weight is firmly latched back into the release
mechanism on top of the guide rod. (Also see ‘Continuous Measuring Mode’
on page 43).
Turn on the device by pressing the ‘START’ button. Enter the ‘MAIN
MENU’ by pressing the ‘SELECT’ button. Use the ‘SELECT’ button to
move the arrow and select ‘CONNECTION’ from the menu. Press the
‘START’ button (SET) to enter the ‘CONNECTION’ menu.
Use the ‘SELECT’ button to move the arrow and select ‘STAND-BY TIME’
from the menu.
Press the ‘START’ button (SET) to enter the ‘STAND-BY TIME’ menu.
The current settings will be displayed.
Using the ‘SELECT’ button you can increase the stand-by time by
5-minute increments, up to a maximum of 30 minutes. Values greater
than zero imply that the testing computer is operating in ‘CONTINUOUS
MEASURING MODE’, and will only switch itself off after an inactivity of
the time set.
Using the ‘PRINT’ button you can decrease the time by 5-minute
increments, up to a minimum of 00 minutes. The testing computer will
operate in ‘SINGLE MEASURING MODE’ if the time is set to ‘00 MIN’.
Press the ‘RESET/OFF’ button (EXIT) to accept the selected time settings
and return to the ‘SERVICE’ menu. Press the ‘RESET/OFF’ button (EXIT)
again to return to the ‘MAIN MENU’. Press the ‘RESET/OFF’ button (EXIT)
again to return to the ‘STATUS REQUEST’. Pressing the ‘START’ button
will start the test procedure. The voice output will confirm if the
‘CONTINUOUS MEASURING MODE’ is turned on successfully by
announcing ‘CONTINUOUS MEASURING MODE ON’.
7.7.7.2 Bluetooth Pairing
The menu entry ‘BLUETOOTH PAIRING’ is reserved for factory settings
and calibration mode. It can be used only by TERRATEST GmbH.
MAIN MENU
PRINT FROM SD-CARD
LANGUAGE
GPS / TIME
INTERNAL MEMORY
SERVICE
CONNECTION
EXIT
SET
→
→
CONNECTION MENU
STAND-BY TIME
BLUETOOTH PAIRING
EXIT
SET
→
→
STAND-BY TIME 00 MIN
EXIT
-
+
STAND-BY TIME 10 MIN
EXIT
-
+