beautypg.com

Cable adjustment (x130-84, x130-94) – Wheatheart X Series 13 Augers User Manual

Page 109

background image

W

HEATHEART

- X13 S

ERIES

A

UGERS

7. M

AINTENANCE

X1374, X1384, X1394

7.3. M

AINTENANCE

P

ROCEDURES

30787 R1

109

• Lift the discharge end of the auger with a front end loader or rest on a bin

so that the tube has a slight upward deflection at the discharge to give the
cable some slack.

• Tighten the long cable’s turnbuckles evenly on both sides so the tube

stays straight.

• Tighten the cables so there is a slight upwards angle on the discharge

end.

• Check the short cable for slack and tighten as necessary.

7.3.14. C

ABLE

A

DJUSTMENT

(X130-84, X130-94)

The cables are properly tightened when:

• There is no slack in the cables.
• The tube is straight side-to-side.

T

IGHTENING

C

ABLES

The location of the cable adjustment points are shown in the accompanying
figure.

1. Lift the discharge end of the auger with a

front end loader so that the tube has a
slight upward deflection at the discharge
to give the cable some slack.

2. Tighten

the

left-side and right-side

turnbuckles equally to increase the
tension in the cable.

3. If the proper cable tension can’t be

obtained before the turnbuckles run out
of adjustment, then do the following:

a. Fully loosen the turnbuckles.

b. At the turnbuckles, loosen the cable

clamps, shorten the cables until there
is tension on the cable, then tighten the cable clamps fully.

c. Return to step 2.

S

TRAIGHTENING

T

HE

T

UBE

If tube is not straight side-to-side:

1. Loosen all cable clamps on truss towers.
1. If the tube is curved to the left, tighten the right-hand turnbuckle and then

loosen the left-hand turnbuckle.

2. If the tube is curved to the right, tighten the left-hand turnbuckle and then

loosen the right-hand turnbuckle.

3. Re-tighten all truss tower cable clamps when the tube is straight.

CABLE CLAMPS

TURNBUCKLE