Profile series v.g1 cylindrical lock, Lock preset to, Lock installation – SARGENT Profile Series v.G1.5 Cylindrical Locks User Manual
Page 8
6
800-810-WIRE (9473) • www.sargentlock.com • A7755A
Profile Series v.G1 Cylindrical Lock
Copyright © 2004, 2008, Sargent Manufacturing Company
, an A
SSA ABL
O
Y
Group company
. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
For wood
door only
Screws partially
tightened
Lock Preset to:
• Through-bolt location– 12 & 6 o'clock
• Door thickness– 1-3/4" thick- see below for other door conditions
Adjustment for different through-bolt and door thickness:
• Through-bolt location– rotate outside rose to match door
• Door thickness– rotate outside rose to align door thickness marking with lockbody edge
• Spacer bushing– remove and realign to fit into back of lever
5. Lock Installation
IMPORTANT:
Door must remain open
during installation.
Use door stop.
IMPORTANT
Lockbody
must be
centered
in the door
3
1-3/4" thick door
2" thick door
Through-bolt
holes
Rotate to match
through-bolt holes in door
Spacer bushing
1. Feed wires into the lock body hole, from outside of door.
2. Lock body into cross-bore hole from outside of the door (locked side).
3. Lock body must engage both the latch unit prongs and tail piece, as shown.