Passport 1000 pg mortise lock, 8 – installation of inside component assembly, 9 - installation of connectors – SARGENT Passport 1000 PG Mortise Locks User Manual
Page 12

PERSONA PG Controller DIP
Switch Settings (Fig 10A):
8 – Installation of Inside Component Assembly
Insert bottom of component assembly first (Fig. 8A), then
clip top of component assembly to backplate, verifying
both tabs attached securely.
9 - Installation of Connectors
Secure the following connectors onto the
circuit board (Fig. 9A1 and 9A2):
Note: Connectors go on only one way.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
1. Secure the mortise lock body as-
sembly connector (10-pin).
2. Secure the mortise keypad/card
reader connector (14-pin).
3. Secure the LCU connector (7-pin).
10 - Battery / Battery Pack Installation and DIP Switch
Setting Verification
1. Place (6) “AA” batteries into the compartment being careful to align
polarity (- & +) properly.
2. Insert battery pack and click into place, making sure polarity terminals on
the battery pack are oriented upwards (Fig. 10A).
3. Verify DIP switch settings are correct for the application.
Fig. 10A
Inside of door
PERSONA PG
controller DIP
switch location
Fig. 8A
From outside trim
(ground)
Detail
From outside trim
(card reader)
From outside
trim (keypad)
From lock body
Fig. 9A1
Fig. 9A2 (Detail)
ON
OFF
ON
OFF
SARGENT mortise lock with and
without deadbolt:
• Switch 1 and 2 - OFF
• Switch 3 - ON
SARGENT cylinder or exit locks:
• Switch 1 - OFF
• Switch 2 and 3 - ON
10/31/12