KP Series
Keypad Mortise Lock
All of the following procedures start with 99# (continued).
If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.
To Interrogate Transaction Log:
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 70# 0# 0# (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Goes Out)
For additional information, see “Transaction Log”.
Hold an infrared printer up to the red
infrared LED (as shown). A Data Transfer
Device (DTD) can be used to download
information from the keypad to a printout.
Illustration
To LED
location
DataTransfer Device
(DTD)
Note: Seq. # 1 is the
programming request
to output the entries.
Sequence numbers 2-6
are the actual entries.
Door # 5666
Seq
User
Trans
1
001
003
2
003
001
3
003
001
4
020
001
5
003
001
Door Number
Transaction
Number
User Number
Transaction
Type
To Reset / Clear Transaction Log
• Master Code
* (Yellow LED Begins to Blink Slowly)
• 76# 00000# 00000# (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Goes Out)
To Delete a User Number:
• Master Code
* (Yellow LED Begins to Blink Slowly)
• User Number# (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Blinks Slowly)
•
* (Yellow LED Goes Out)
To Disable / Enable a User Number:
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 56# 0# = Enable, 1# = Disable User Number# (04-99) (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Blinks Slowly)
•
* (Yellow LED Goes Out)
To Set Unlock Time:
• Master Code
* (Yellow LED Begins to Blink Slowly)
• 85# Time Duration# (01-99 Sec) 0# (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Blinks Slowly)
•
* (Yellow LED Goes Out)
Note:
The Unlock Time is Adjustable for Momentary Operation. A 5 second unlock time is recommended to extend battery life.
Once the unlock time is entered, it is the same for ALL users except 02, 98 and 99 which are factory set for 10 seconds.