Kp series keypad mortise lock – SARGENT Keypad Exit Devices User Manual
Page 20

20 1-800-810-WIRE • www.sargentlock.com • A7373C
Copyright © 2014, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
03/31/14
KP Series
Keypad Mortise Lock
To Enter a Passage (Maintained Mode) Code:
All of the following procedures start with 99# (continued).
If after the last “
*
” is depressed, the yellow LED does not go out, depress “*” once more.
When Passage Mode is used,
the same User Code must be used to re-lock the lock.
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 50# 2# User Number (04-97)# User Code
* (Yellow LED Blinks Quickly)
• User Code
* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)
To Enter a One Time User Code:
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 50# 3# User Number# User Code
* (Yellow LED Blinks Quickly)
• User Code
* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)
To Deactivate “Beep” With the Depression of Each Key:
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 30# 0# 0# (Yellow LED Continues to Blink Slowly)
•
* (Yellow LED Blinks Quickly)
•
* (No Beep on Depression and Yellow LED Blinks Slowly)
•
* (No Beep on Depression and Yellow LED Goes Out)
To Reactivate “Beep” With the Depression of Each Key:
• Supervisory or Master Code
* (Yellow LED Begins to Blink Slowly)
• 30# 0# 1# (Yellow LED Continues to Blink Slowly)
•
* (Yellow LED Blinks Quickly)
•
* (Beep on Depression and Yellow LED Blinks Slowly)
•
* (Beep on Depression and Yellow LED Goes Out)
To Clear the Entire Memory:
• Master Code
* (Yellow LED Begins to Blink Slowly)
• 46# 00000# 00000# (Yellow LED Continues to Blink Slowly)
•
* (Yellow LED Blinks Quickly)
•
* (No Beep on Depression and Yellow LED Goes Out)
• PAUSE, Yellow LED Begins to Blink Again
•
* (Yellow LED Goes Out)
NOTE This Deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back
to 1234, Door Number to 0001 and Unlock time to 5 Sec. If the Master Code is not known, Factory
Assistance will be required to clear the memory. 1-800-810-WIRE.
To Program Door Numbers into Keypad:
• Master Code
* (Yellow LED Begins to Blink Slowly)
• 43# 0# Door Number# (must be four digits) (Yellow LED Blinks Slowly)
•
* (Yellow LED Begins to Blink Quickly)
•
* (Yellow LED Blink Slowly)
•
* (Yellow LED Goes Out)