How to read the at10.1 model number, Group i ratings (6-25 adc), At10 x x – Exide Technologies Section 94.20 User Manual
Page 2

HOW TO READ THE AT10.1 MODEL NUMBER
GROUP I RATINGS (6-25 Adc)
Your AT10.1 model number is coded to describe the options that are included. Please find the model
number on the data nameplate and write it in the spaces provided below. Then follow the chart to
determine the configuration of your battery charger.
AT10
X X
A
B
C D E F K L
M
N
P
Q
R
DESCRIPTION CODE FEATURE
DESCRIPTION CODE FEATURE
A
SERIES AT10
AT10.1
CHARGER
S
STANDARD
012
12 Vdc
M
MEDIUM AIC
024 24
Vdc
F
CIRCUIT
BREAKER
RATING
(SEE TABLE)
H HIGH
AIC
048 48
Vdc
B
NOMINAL
DC OUTPUT
VOLTAGE
130 130
Vdc
AUX SUPPLIED
006 6
Adc
K
AUX ALARM
RELAY BOARD
XXX NOT
SUPPLIED
012 12
Adc
016 16
Adc
G SUPPLIED
020 20
Adc
L
GROUND PAD
X NOT
SUPPLIED
C
NOMINAL
DC OUTPUT
CURRENT
025 25
Adc
U UNFILTERED
L SUPPLIED
F FILTERED
M
LIGHTNING
ARRESTOR
X NOT
SUPPLIED
D
FILTERING
E ELIMINATOR
120
120 Vac 60 Hz
1
F
APPLIED
208
208 Vac 60 Hz
1
N
FUNGUS
PROOFING
X NOT
APPLIED
240
240 Vac 60 Hz
1
S
APPLIED
480
480 Vac 60 Hz
2
P
STATIC
PROOFING
X NOT
APPLIED
220
220 Vac 50/60 Hz
3
380
380 Vac 50/60 Hz
3
Q
NOT USED
X
E
AC INPUT
VOLTAGE
416
416 Vac 50/60 Hz
3
R
NOT USED
X
DESCRIPTION CODE FEATURE
DESCRIPTION CODE FEATURE
1 - 120/208/240 Vac multi-tap input - Unit is wired and shipped from factory at specified voltage.
2 - 480 Vac input requires addition of medium or high ampere interrupting capacity circuit breakers.
3 - Special order, consult factory for availability.
INPUT AND OUTPUT CIRCUIT BREAKER INTERRUPTING RATINGS
CODE TYPE
AC RATINGS
(ALL INPUT VOLTAGES)
DC RATINGS
(125 Vdc)
S
STANDARD
240 Vac: 10,000 AIC
10,000 AIC
4
5,000 AIC
5
M MEDIUM
AIC
240 Vac: 25,000 AIC
480 Vac: 18,000 AIC
10,000 AIC
H HIGH
AIC
240 Vac: 65,000 AIC
480 Vac: 25,000 AIC
20,000 AIC
4 - Rating applies to 130Vdc 16-25 Adc units.
5 - Approximate rating applies to all other units.
NOTE
The model number listed on the charger data nameplate does not include any field-installed
options. Also, certain accessories are not included in the model number, even if they are shipped with the
charger. Check off below any accessories that were included, or that you install yourself.
floor/rack
mounting
brackets
analog ac voltmeter (penthouse-mounted)
NEMA-2 type drip shield assembly
analog ac ammeter (penthouse-mounted)
NEMA-4/12/13
type
enclosure
barrier type auxiliary alarm terminal block(s)
cabinet
heater
assembly
external temperature compensation probe
pad lock for front panel door
DNP3 Level 2 / Modbus communications module
zero-center ground detect meter
forced load sharing interconnection cable
Please find the serial number on the