beautypg.com

Weldskill 200ac/dc inverter – Tweco 200DC Inverter Arc Welding Machine User Manual

Page 29

background image

WELDSKILL 200AC/DC INVERTER

Manual 0-5207

3-11

INSTALLATION, OPERATION AND SETUP

Up Slope

This parameter operates in (4T)

TIG modes only and is used to

set the time for the weld current

to ramp up, after the torch trigger

switch has been pressed then

released, from INITIAL CUR to

PEAK or BASE current.

Volts

VOLTS
SECONDS

PERCENT (%)
FREQ (Hz)

15.0

0.0 to 15.0 seconds

Base Current

This parameter sets the TIG

WELD current when PULSE is

OFF. This parameter also sets the

STICK weld current.

Amps

200

5 to 200A (DC TIG mode)

30 to 200A (AC LIFT TIG mode)

10 to 200A (AC HF TIG mode)

Peak Current

This parameter sets the PEAK

weld current when in PULSE

mode.

Amps

200

10 to 200A (DC TIG mode)

30 to 200A (AC TIG mode)

Trough Current

The lowest point in the pulse is

called the Trough.

Amps

200

5 to 200A (DC HF TIG mode)

30 to 200A (AC LIFT TIG mode)

10 to 200A (AC HF TIG mode)

Pulse Width

This parameter sets the

percentage on time of the PULSE

FREQUENCY for PEAK weld

current when the PULSE is ON.

Volts

0

VOLTS
SECONDS

PERCENT (%)
FREQ (Hz)

8

15 to 80%

Pulse Frequency

This parameter sets the PULSE

FREQUENCY when the PULSE is

ON..

200

Volts

VOLTS
SECONDS

PERCENT (%)
FREQ (Hz)

0.5 to 200 Hz

Down Slope

This parameter operates in TIG

modes only and is used to set

the time for the weld current

to ramp down, after the torch

trigger switch has been pressed,

to crater current. This control is

used to eliminate the crater that

can form at the completion of a

weld.

Volts

VOLTS
SECONDS

PERCENT (%)
FREQ (Hz)

25.0

0.0 to 25.0 seconds

Crater Current

This parameter operates in (4T)

TIG modes only and is used to

set the finish current for TIG.

The CRATER Current remains

ON until the torch trigger switch

is released after it has been

depressed.

Note: The maximum crater

current available will be limited to

the set value of the base current.

Amps

200

VOLTS
SECONDS

PERCENT (%)
FREQ (Hz)

5 to 200A (DC TIG mode)

30 to 200A (AC TIG mode)

10 to 200A (AC HF TIG mode)

This manual is related to the following products: