10 specifications, 10 specifications -5, Weldskill 200ac/dc inverter – Tweco 200DC Inverter Arc Welding Machine User Manual
Page 17
WELDSKILL 200AC/DC INVERTER
Manual 0-5207
2-5
INTRODUCTION
2.10 Specifications
Description
WELDSKILL 200 AC/DC
Plant Part Number
W1006200
Power Source Mass
22 kg
Power Source Dimensions
H 400mm x W 240mm x D 475mm
Cooling
Fan Cooled
Welder Type
Inverter Power Source
Australian Standards
AS 60974.1-2006 / IEC 60974-1
Number of Phases
1
Nominal Supply Voltage
240V +/- 15%
Nominal Supply Frequency
50/60Hz
Welding Current Range (DC STICK Mode)
5 – 170A
Welding Current Range (DC TIG Mode)
5 - 200A
Effective Input Current (I
1eff
) (note1)
15A
Maximum Input Current (I
1max
)
38.8A
Single Phase Generator Requirement
(note2)
10kVA
STICK (MMAW)
Welding Output, 40ºC, 10 min.
170A @ 15%, 26.8V
100A @ 60%, 24.0V
80A @ 100%, 23.2V
TIG (GTAW)
Welding Output, 40ºC, 10 min.
200A @ 20%, 18.0V
116A @ 60%, 14.6V
90A @ 100%, 13.6V
Open circuit voltage
76V
Protection Class
IP23S
Table 2-1: WELDSKILL 200AC/DC Specification
NOTE
Note 1: The Effective Input Current should be used for the determination of cable size & supply
requirements.
Note 2: Generator Requirements at the Maximum Output Duty Cycle.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application. Check
local requirements for your situation in this regard.
Due to variations that can occur in manufactured products, claimed performance, voltages, ratings,
all capacities, measurements, dimensions and weights quoted are approximate only. Achievable
capacities and ratings in use and operation will depend upon correct installation, use, applications,
maintenance and service.