beautypg.com

Weldskill 200ac/dc inverter – Tweco 200DC Inverter Arc Welding Machine User Manual

Page 25

background image

WELDSKILL 200AC/DC INVERTER

Manual 0-5207

3-7

INSTALLATION, OPERATION AND SETUP

9. Wave Balance / Arc Force Indicator

This indicator light will illuminate when programming Wave Balance (AC HF TIG mode only) or Arc Force

(STICK mode only).

10. Forward Programming Button

Pressing this button will advance to the next step in the programming sequence.

11. Multifunction Control

The multifunction control knob is used to adjust welding current.

It is also used to adjust parameters when in programming mode.

12. Back Programming Button

Pressing this button will go back to the previous step in the programming sequence.

13. AC frequency Indicator

This indicator light will illuminate when programming AC Frequency (AC HF TIG mode only).

14. Purge Button

Press and hold the PURGE button to purge the gas line in LIFT TIG and HF TIG modes. To PURGE the

shielding gas line in LIFT TIG and HF TIG modes press the PURGE button and release. The indicator will

illuminate and shielding gas will purge for a preset period of 15 seconds. (This cannot be adjusted). To stop

shielding gas from purging within this time press the PURGE button and release and the purge indicator

will extinguish and shielding gas will cease.

15 Pulse Button

Press the PULSE button to toggle Pulse On and OFF in LIFT TIG and HF TIG modes

16. Programming Parameter Indicators

These indicator lights will illuminate when programming.

17. Mode Button

Press the MODE button to toggle AC and DC output in all Process modes

18. Digital Ammeter

The digital amperage meter is used to display both the pre-set current and actual output current of the

power source.

At times of non-welding, the amperage meter will display a pre-set (preview) amperage value. This value

can be adjusted by varying the multifunction control when the Programming Parameter Indicator light

shows BASE CURRENT.

When welding, the amperage meter will display actual welding current.

Should a remote device be connected the maximum setting of the power source will be determined by the

respective front panel control, irrespective of the remote control device setting. As an example, if the output

current on the power source front panel is set to 50% and the remote control device is set to 100%, the

maximum achievable output from the unit will be 50%. Should 100% output be required, the respective

power source front panel control must be set to 100%, in which case the remote device will then be able

to control between 0-100% output.