WELDSKILL 200AC/DC INVERTER

Manual 0-5207

3-3

INSTALLATION, OPERATION AND SETUP

C. Methods of Reducing Electromagnetic Emissions

1. Mains Supply
Welding equipment should be connected to the mains supply according to the manufacturer’s

recommendations. If interference occurs, it may be necessary to take additional precautions such as

filtering of the mains supply. Consideration should be given to shielding the supply cable of permanently

installed welding equipment in metallic conduit or equivalent. Shielding should be electrically continuous

throughout its length. The shielding should be connected to the Welding Power Source so that good

electrical contact is maintained between the conduit and the Welding Power Source enclosure.

2. Maintenance of Welding Equipment
The welding equipment should be routinely maintained according to the manufacturer’s recommendations.

All access and service doors and covers should be closed and properly fastened when the welding

equipment is in operation. The welding equipment should not be modified in any way except for those

changes and adjustments covered in the manufacturer’s instructions. In particular, the spark gaps of

arc striking and stabilising devices should be adjusted and maintained according to the manufacturer’s

recommendations.

3. Welding Cables
The welding cables should be kept as short as possible and should be positioned close together, running

at or close to the floor level.

4. Equipotential Bonding
Bonding of all metallic components in the welding installation and adjacent to it should be considered.

However. Metallic components bonded to the work piece will increase the risk that the operator could

receive a shock by touching the metallic components and the electrode at the same time. The operator

should be insulated from all such bonded metallic components.

5. Earthing of the Workpiece
Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of it’s

size and position, e.g. ship’s hull or building steelwork, a connection bonding the workpiece to earth

may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of

the workpiece increasing the risk of injury to users, or damage to other electrical equipment. Where

necessary, the connection of the workpiece to earth should be made by direct connection to the

workpiece, but in some countries where direct connection is not permitted, the bonding should be

achieved by suitable capacitance, selected according to national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables and equipment in the surrounding area may alleviate

problems of interference. Screening the entire welding installation may be considered for special

applications.