06 stick (smaw) setup – Tweco 201 ts Thermal Arc User Manual
Page 24

THERMAL ARC 161 STL, 201 TS
INSTALLATION
Installation 3-6
Manual 0-5203
Figure 3-2: Setup for STICK (SMAW) Welding
3.06 STICK (SMAW) Setup
200A
Set Welding Current
as specified by the
Electrode Manufacturer.
Set Process Selection
Switch to STICK.
Set ARC Force
Positive Output
Terminal
(Dinse™ 50)
Negative Output
Terminal
(Dinse™ 50)
Art#: A-09784
STICK (SMAW) Mode Sequence of Operation
CAUTION
Before any welding is to begin, be sure to
wear all appropriate and recommended safety
equipment.
1. Switch the ON/OFF Switch (located on the rear panel)
to OFF.
2. Connect the ground (work) clamp cable to the negative
output terminal, and the electrode holder cable to
the positive output terminal. It is essential that the
male plug is inserted and turned fully clockwise until
connector locks in place to achieve reliable electrical
connection.
NOTE
This set up is known as DC Electrode Positive
or reverse polarity. Please consult with the
stick electrode manufacturer for specific
polarity recommendations.
3. Connect the ground (work) clamp to your workpiece.
4. Plug the power cable into the appropriate outlet, and
turn the switch to the “ON” position. The power L.E.D
light should illuminate.
5. Set the “Process Selection Switch” to STICK.