beautypg.com

06 stick (smaw) setup – Tweco 201 ts Thermal Arc User Manual

Page 24

background image

THERMAL ARC 161 STL, 201 TS

INSTALLATION

Installation 3-6

Manual 0-5203

Figure 3-2: Setup for STICK (SMAW) Welding

3.06 STICK (SMAW) Setup

200A

Set Welding Current
as specified by the
Electrode Manufacturer.

Set Process Selection
Switch to STICK.

Set ARC Force

Positive Output
Terminal
(Dinse™ 50)

Negative Output
Terminal
(Dinse™ 50)

Art#: A-09784

STICK (SMAW) Mode Sequence of Operation

CAUTION

Before any welding is to begin, be sure to

wear all appropriate and recommended safety

equipment.

1. Switch the ON/OFF Switch (located on the rear panel)

to OFF.

2. Connect the ground (work) clamp cable to the negative

output terminal, and the electrode holder cable to

the positive output terminal. It is essential that the

male plug is inserted and turned fully clockwise until

connector locks in place to achieve reliable electrical

connection.

NOTE

This set up is known as DC Electrode Positive

or reverse polarity. Please consult with the

stick electrode manufacturer for specific

polarity recommendations.

3. Connect the ground (work) clamp to your workpiece.
4. Plug the power cable into the appropriate outlet, and

turn the switch to the “ON” position. The power L.E.D

light should illuminate.

5. Set the “Process Selection Switch” to STICK.

This manual is related to the following products: