Tweco 201 ts Thermal Arc User Manual
Page 18

THERMAL ARC 161 STL, 201 TS
INTRODUCTION
Introduction
2-4
Manual 0-5203
2.08 Specifications -201 TS
Power Source Part Number
W1003806
Mains Power
Nominal Supply Voltage
AC 115V
AC 208/230V
Number of Phases
Single Phase
Single Phase
Input Voltage Range
AC 104- 127V
AC 187- 253V
Nominal Supply Frequency
50/60 Hz
50/60 Hz
Effective Input Current (l1eff) for STICK (SMAW) Welding
18.3 Amps
15.8/14.2 Amps
Effective Input Current (l1eff) for LIFT TIG/HF TIG (GTAW)
Welding
16.4 Amps
12.3/11.1 Amps
Maximum Input Current (l1 max) for STICK (SMAW) Welding
∆ 27.2 Amps
∆ 35.2/31.6 Amps
Maximum Input Current (l1 max) for LIFT TIG/HF TIG (GTAW)
Welding
∆ 23.2 Amps
∆ 24.6/22.1 Amps
Single Phase Generator Requirements [Continuous rating
at nominal supply voltage with maximum output for STICK
(SMAW) welding]
4 KVA
7.3 KVA
Welding Output
Welding Current Range
Stick: 10 - 125 Amps
TIG: 10 - 160 Amps
Stick/TIG:
10 - 200 Amps
Nominal DC Open Circuit Voltage (OCV)
71V
71V
Welding Output, 104º F (40º C), 10 min.
(Quoted figures refer to STICK (SMAW) output)
100A @ 45%, 24.0V
87A @ 60%, 23.5V
68A @ 100%, 22.7V
200A @ 20%, 28V
116A @ 60%, 24.6V
90A @ 100%, 23.6V
Rated Input Current (A)
For STICK (SMAW) Welding
27.2A
Io = 100A @ 24.0V
35.2/31.6A
Io = 200A @ 28V
Rated Input Current (A)
For LIFT TIG (GTAW) Welding
23.2A
Io = 125A @ 15.0V
24.6/22.1A
Io = 200A @ 18V
Rated Output for STICK (SMAW) Welding
24.0V, 100A @ 45%
28V, 200A @ 20%
Rated Output for LIFT TIG/HF TIG (GTAW) Welding
15.0V, 125A @ 50%
18V, 200A @ 25%
Duty Cycle (%)
45% @ 100A
20% @ 200A
Welder Type
Inverter Power Source
Output Terminal Type
Heavy Duty Dinse
TM
50
Classification
Protection Class
IP21S
Standards
CSA E60974-1
EN50199
Cooling Method
Fan Cooled
Dimensions and Weight
Welding Power Source Mass
22 lb. (10 kg)
Welding Power Source Dimensions (Height x Width x Depth)
H 9.0” x W 5.3” x D 17.7”
(H230mm x W135mm x D450mm)
∆
The recommended time delay fuse or circuit breaker size is 30 amp. An individual branch circuit capable of carrying 30 amperes
and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent
of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the speci-
fications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold
or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above specifications
due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components, installation location
and conditions and local power grid supply conditions.
The Welding power source is of a drooping characteristic. The thermal protection switch is rated at 75° C.