beautypg.com

Appendix 5: system schematic, 208/460v units, Cutmaster 102, L2 l1 gnd l3 – Tweco 102 Cutmaster User Manual

Page 78

background image

CUTMASTER 102

APPENDIX

Manual 0-4997

A-6

APPENDIX 5: SYSTEM SCHEMATIC, 208/460V UNITS

+12VDC

+12VDC

+12VDC

+12VDC

+12VDC

+5VDC

+12VDC

+12VDC

+12VDC

+12VDC

+12VDC

24VAC

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE:

Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.

Capacitors are in Microfarads (UF)

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

42X1315

1

1

16052 Swingley Ridge Road

Suite 300

St Louis, MO 63017 USA

CUTMASTER 102/152/A80/A120 230/460V

09:02:19

VICTOR TECHNOLOGIES

VICTOR TECHNOLOGIES

VICTOR TECHNOLOGIES

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE:

Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.

Capacitors are in Microfarads (UF)

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

42X1315

Friday, December 11, 2009

1

1

16052 Swingley Ridge Road

Suite 300

St Louis, MO 63017 USA

CUTMASTER 102/152/A80/A120 230/460V

09:02:19

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE:

Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.

Capacitors are in Microfarads (UF)

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

42X1315

1

1

16052 Swingley Ridge Road

Suite 300

St Louis, MO 63017 USA

CUTMASTER 102/152/A80/A120 230/460V

09:02:19

D

_

OVER PRESSURE

INTERNAL ERROR

SHORTED TORCH

CONSUMABLES MISSING

START ERROR

PARTS IN PLACE

INPUT POWER

UNDER PRESSURE

ERROR IND FAULT

PCB3

INRUSH

RESISTORS

LATCH

SET

RUN

RAR

MAX

90

85

80

75

70

65

MIN

TP1

TP2

TP3

TP4

TP5

TP6

TP7

LOGIC PCB

GND

+12 VDC

+5 VDC

3.3 VDC

0.v - 5.0 VDC / 0-100PSI

1.8 VDC

CURRENT DEMAND

TEST POINTS

TEMP

CIRCUIT

3.3VDC

TXD

RXD

Q2

D

SERIAL PORT

80

81

82

83

E64

E35

78
79

-

+

* CM102 & A80

C7 & C10 not installed

ATC CONNECTOR

GND1

GND2

+12V1

48V1

I_DMD_1

TIP_SEN

COMMON

COMMON

+12 VDC SUPPLY

+48 VDC SUPPLY

CURRENT DEMAND

TIP DRAG SENSE

TEST POINTS

A120 ONLY

J2

_

J1

/460

/230

CNC PINOUT

1

3

4

7

8

11

12

14

OK-TO-MOVE

/PIP

PCB1

+

+

+

+

Q1

/START

/SOLENOID

24VAC RETURN

24VAC SUPPLY

MAIN PCB ASSY

/OVERTEMP

TEMP

CIRCUIT

PRESSURE

TRANSDUCER

AIR

INLET

FILTER

REGULATOR

SOLENOID

VALVE

ATC

GAS CONTROL

0-100PSI / 0-4.5VDC

/INRUSH

/OVERTEMP

D3

D1

(5A @ 250VAC / 30VDC)

C

D

B

A

1TORCH

_

AUTOMATION

TORCH SOLENOID

Q2

_

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

29

34

35

36

37

38

39

-V_OUT_SIGNAL

/TIP_VOLTS

/TIP_SENSE

/460V_IN

/230V_IN

CUR_SET

/RAR (RAPID AUTO RESTART)

/INRUSH

/W1_ON

SHDN

/TORCH_SOLENOID

/SOLENOID_ON

/OK_TO_MOVE

/FAN_ON

/LATCH_ACTIVE

/TORCH_SWITCH

/PIP

AC_ON

CSR

/TORCH_SOLENOID_DETECT

/OVERTEMP

V_IN

+12VDC

+12VDC

COMMON

COMMON

MAIN_PCB_ID

460_IN

+3.3VDC

TXD

RXD

COMMON

D

M-L

M-L

M-L

L-M

L-M

L-M

L-M

L-M

L-M

L-M

L-M

L-M

L-M

L-M

L-M

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

M-L

L-M

M-L

M-L

L-M

M-L

40 PIN RIBBON CABLE SIGNALS

B

A

PCB5

40/50 AMP PCB

PCB2

Q1

FAN

/FAN

FAN

D2

D1

C

D

INPUT CAPACITOR PCB

JANUARY 31, 2008

1 /OVERTEMP

2 /FAN_ON

3 /CSR

4 CUR_SET

5 MAIN_PCB_ID

6 COMMON

SYNC

}

OK-TO-MOVE

OK TO MOVE

}

}

PCB4

AUTOMATION

INTERFACE PCB

FULL FEATURED AUTOMATION INTERFACE PCB OPTION

(+)

}

To configure DIVIDED ARC VOLTS signal output

No jumper installed for ARC VOLTS / 16.67

Jumper pins 1 & 2 for ARC VOLTS / 30

Jumper pins 2 & 3 for ARC VOLTS / 50

K1

To -V OUT 1

on PCB1

}

/START / STOP

*

*

}

DIVIDED ARC VOLTS

/START / STOP

(+)

(-)

(W/ 100K IN SERIES (2))

(-)

*

ARC VOLTS

SYNC

FAN

INPUT VOLTAGE SELECTOR

(Closed for 230VAC input)

460_IN

9

8

7A

*

PRIMARY POWER

CONNECTIONS:

FOR 3 PH:

REMOVE BUSS BARS/JUMPERS

BETWEEN L1 TO L4 & L2 TO L3

CONNECT PRIMARY INPUT CABLE

TO L1,L2,L3 & GND

FOR 1PH:

INSTALL BUSS BARS/JUMPERS

BETWEEN L1 TO L4 & L2 TO L3

CONNECT PRIMARY INPUT CABLE

TO BUSS BARS (L1/L4) & (L2/L3)

*

L1

L2

L4

L3

T2

T1

T4

T3

24VAC RET

5

AC INPUT

PRIMARY

6

7

BUSS BARS/JUMPERS

L2

L1

GND

L3

/FAN

AA

INTRO ECO-B935

MNC 05/21/08

BIAS

SUPPLY

+12VDC

BIAS

SUPPLY

FERRITE

FILTER

FERRITE

FILTER

MNC

AB

MNC

AC

MNC

AD

RWH 03/31/09

ECO B1192

8

0

/

1

1

/

9

0

6

1

1

1

B

O

C

E

11/01/08

ECO B1357

CNC INTERFACE STANDARD ON A80 & A120 UNITS

CNC INTERFACE OPTIONAL ON CM102 & CM152 UNITS

MTH7

MTH7

J2

J2

2

3

4

5

6

7

8

9

10

11

12

13

14

1

AC2

AC2

AC

AC

J9

J9

NTC

NTC

-V OUT 1

-V OUT 1

J2

J2

1

2

AC3

AC3

WORK1

WORK1

TP3

TP3

MTH4

MTH4

SOL 1

SOL 1

CHOKE1

CHOKE1

+ C3,C4,C7,C8*

+ C3,C4,C7,C8*

MOT3

MOT3

+

-

SW2

SW2

90

90

J14

J14

SEC1

SEC1

MTH6

MTH6

J1

J1

2

3

4

5

6

7

8

9

10

11

12

13

14

1

PMTH2

PMTH2

TS1

TS1

SEC1

SEC1

80A_AC3

80A_AC3

PRI 3

PRI 3

J10

J10

1

2

3

4

5

6

7

8

J13

J13

1 2 3 4 5 6

80A_AC2

80A_AC2

Q5

PILOT IGBT

Q5

PILOT IGBT

PRI 2

PRI 2

J1

J1

1

2

3

J3

J3

3

2

1

K1

K1

NTC

NTC

ERROR

ERROR

K5

K5

L2

L2

PRI 2

PRI 2

AC1

AC1

J4

J4

1

2

3

4

5

MTH8

MTH8

+

C16-17

+

C16-17

85

85

K1

K1

70

70

PRI 4

PRI 4

TIP1

TIP1

K6

K6

SW1

SW1

1

3

2

4

MTH2

MTH2

T1

T1

J7

J7

1

2

1 2 3

D78 CSR

D78 CSR

MIN

MIN

W1

W1

J4

J4

1 2 3 4 5 6 7 8 9 10

ELECTRODE1

ELECTRODE1

PMTH3

PMTH3

TORCH SWITCH

TORCH SWITCH

PRI 1

PRI 1

PMTH1

PMTH1

MOT1

MOT1

+

-

40A_AC2

40A_AC2

P2

P2

1

2

3

4

5

6

7

8

AC2

AC2

J1

J1

1

2

SEC2

SEC2

PMTH1

PMTH1

K3,K4

K3,K4

W1

W1

AC1

AC1

SEC2

SEC2

MOT2

MOT2

+

-

K2

K2

+

C12-13

+

C12-13

J5

J5

1

2

3

Current Control

Current Control

MAX

MAX

CHOKE1

CHOKE1

DC

DC

PRI 1

PRI 1

TP4

TP4

J12

J12

1

2

3

J1

J1

1

2

3

4

5

6

7

8

PRI 3

PRI 3

TP2

TP2

PRI 4

PRI 4

AC3

AC3

PMTH4

PMTH4

65

65

GAS

GAS

J1

J1

1

2

3

4

5

80A_AC1

80A_AC1

J6

J6

1

2

J11

J11

1 2

T2

T2

PRI 1

PRI 1

+OUT_1

+OUT_1

K4

K4

P10

P10

1

2

3

4

5

6

7

8

TP5

TP5

K1,K2

K1,K2

J3

J3

1

2

OVERTEMP

OVERTEMP

L1

L1

P1

P1

1 2 3

40A_AC3

40A_AC3

80

80

MTH1

MTH1

PMTH4

PMTH4

D1

D1

TP8

TP8

+

C5,C6,C9,C10*

+

C5,C6,C9,C10*

TP1

TP1

K5,K6

K5,K6

PIP SWITCH

PIP SWITCH

75

75

PRI 2

PRI 2

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

K3

K3

P10

P10

1

2

3

4

5

6

7

8

J2

J2

1

2

PMTH2

PMTH2

WORK

WORK

J9

J9

1

2

3

4

5

6

7

E1

E1

PMTH3

PMTH3

J3

J3

1 2

D59 PCR

D59 PCR

40A_AC1

40A_AC1

K1

K1

A-09132_AC

A-09132_AC

AD

ECO B1611

RWH 12/11/09