Section 4 system: operation, 01 front panel controls / features, Section 4 system – Tweco 102 Cutmaster User Manual
Page 31: Operation -1, Front panel controls / features -1, Cutmaster 102
![background image](/manuals/595195/31/background.png)
CUTMASTER 102
Manual 0-4997
OPERATION
4-1
SECTION 4 SYSTEM:
OPERATION
4.01 Front Panel Controls / Features
See Illustration for numbering Identification
1. Output Current Control
Sets the desired output current. Output settings up to
60 Amps may be used for drag cutting (with the torch tip
contacting the workpiece) or higher for standoff cutting.
2. Function Control
Function Control Knob, Used to select between the different
operating modes.
SET
Used to purge the air through the unit and
torch and leads and to adjust gas pressure.
RUN
Used for general cutting operations
RAPID AUTO RESTART
Allows for faster restart-
ing of the Pilot Arc for uninterrupted cutting.
LATCH
Used for longer hand held cuts.
Once a cutting arc is established, the torch switch can
be released. The cutting arc will remain ON until the
torch is lifted away from the work piece, the torch leaves
the edge of the work piece the torch switch is activated
again or if one of the system interlocks is activated.
3. ON OFF Power Switch
ON / OFF
Switch controls input power to the power
supply. Up is ON, down is OFF.
4. Air/Gas Pressure Control
The Pressure
+
Control is used in the "SET"
mode to adjust the air/gas pressure. Pull the knob out to
adjust and push in to lock.
5.
AC Indicator
Steady light indicates power supply is ready for operation.
Blinking light indicates unit is in protective interlock mode.
Shut unit OFF, shut OFF or disconnect input power, correct
the fault, and restart the unit. Refer to Section 5 for details.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1
2
3
4
5 6 7 8 9
Art# A-07886
MIN
MAX
10
6.
Temp Indicator
Indicator is normally OFF. Indicator is ON when internal
temperature exceeds normal limits. Let the unit cool before
continuing operation.
7.
Gas Indicator
Indicator is ON when minimum input gas pressure for
power supply operation is present. Minimum pressure for
power supply operation is not sufficient for torch operation.
8.
DC Indicator
Indicator is ON when DC output circuit is active.
9.
!
Fault Error Indicator
Indicator is ON when Fault circuit is active. See section 5
for explanations of fault lights.
10. Pressure Indicators
PSI
BAR
MAX
MAX
MIN
MIN
80
75
70
65
5.5
85
5.9
90
6.3
5.2
4.8
4.5
Art # A-08170
The Indicators will illuminate according to the pressure set
by the Pressure Control Knob (number 4).