STANDOFF

CutMaster 102 Gas Pressure Settings

Leads

Length

SL100

(Hand Torch)

SL100

(Mechanized Torch)

Up to 25'

(7.6 m)

75 psi

5.2 bar

75 psi

5.2 bar

Each additional

25' (7.6 m)

Add 5 psi

0.4 bar

Add 5 psi

0.4 bar

3. For Drag cutting (60 Amps and below), adjust gas

pressure from 75 - 95 psi / 5.2 - 6.5 bar (LED's in

center of control panel). Refer to the Drag Cutting

chart for pressure setting details.

DRAG

CutMaster 102 Gas Pressure Settings

Leads

Length

SL100

(Mechanized Torch)

Up to 25'

(7.6 m)

80 psi

5.5 bar

Each additional

25' (7.6 m)

Add 5 psi

0.4 bar

Select Current Output Level

1. Place the Function Control Knob in one of the three

operating positions available:

RUN

,

RAPID AUTO RESTART

or LATCH

. Gas flow stops.

2. Set the output current to desired amperage with the

Output Current Control Knob.

Cutting Operation

When the torch leaves the workpiece during cutting opera-

tions with the Function Control Knob in the RUN position,

there is a brief delay in restarting the pilot arc. With the

knob in the RAPID AUTO RESTART position, when the torch

leaves the workpiece the pilot arc restarts instantly, and the

cutting arc restarts instantly when the pilot arc contacts the

workpiece. (Use the 'Rapid Auto Restart' position when

cutting expanded metal or gratings, or in gouging or trim-

ming operations when an uninterrupted restart is desired).

And with the knob in the LATCH position the main cutting

arc will be maintained after the torch switch is released.

Typical Cutting Speeds

Cutting speeds vary according to torch output amperage,

the type of material being cut, and operator skill. Refer to

Section 4T.08 and following for greater details.

Output current setting or cutting speeds may be reduced

to allow slower cutting when following a line, or using

a template or cutting guide while still producing cuts of

excellent quality.

Postflow

Release the trigger to stop the cutting arc. Gas continues

to flow for approximately 20 seconds. During post - flow, if

the user moves the trigger release to the rear and presses

the trigger, the pilot arc starts. The main arc transfers to

the workpiece if the torch tip is within transfer distance to

the workpiece.

Shutdown

Turn the ON / OFF

switch to OFF

(down). All

Power Supply indicators shut OFF. Unplug the input power

cord or disconnect input power. Power is removed from

the system.