Cutmaster 102 – Tweco 102 Cutmaster User Manual
Page 61
CUTMASTER 102
Manual 0-4997
SERVICE
5-7
5. Remove the fitting from the filter element assembly
by inserting a 6 mm hex wrench into the internal
hex fitting and turning it counter clock-wise (left).
Numbers 4 and 5 in the previous illustration.
6. Disconnect the input line from the filter element as-
sembly.
7. Remove the filter element assembly through the rear
opening.
NOTE
If replacing or cleaning just the filter element refer
to the following illustration for disassembly.
Art # A-07990
Filter Element
8. Install the new or cleaned assembly by reversing
these procedures.
9. Turn ON the air supply and check for leaks before
reinstalling the cover.
Optional Single-Stage Filter Element Replacement
These instructions apply to power supplies where the optional
Single-Stage Filter has been installed.
The Power Supply shuts down automatically when the Filter
Element becomes completely saturated. The Filter Element
can be removed from its housing, dried, and reused. Allow
24 hours for Element to dry. Refer to Section 6, Parts List, for
replacement filter element catalog number.
1. Remove power from power supply.
2. Shut OFF air supply and bleed down system before
disassembling Filter to change Filter Element.
3. Disconnect gas supply hose.
4. Turn the Filter Housing Cover counter-clockwise and
remove it. The Filter Element is located inside the
Housing.
Art # A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
O-ring
(Cat. No. 9-7743)
Optional Single-Stage Filter Element Replacement
5. Remove the Filter Element from the Housing and set
Element aside to dry.
6. Wipe inside of housing clean, then insert the replace-
ment Filter Element open side first.
7. Replace Housing on Cover.
8. Reattach gas supply.
NOTE
If unit leaks between housing and cover, inspect
the O-Ring for cuts or other damage.