INSTALLATION

Manual 0-4997

3-2

3.04 Primary Input Power Connections

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. Check the Voltage Selector at

the rear of the unit for correct setting before plugging in or connecting the unit. The primary power source, fuse, and

any extension cords used must conform to local electrical code and the recommended circuit protection and wiring

requirements as specified in Section 2.

The following illustration and directions are for changing phase of the power supply.

Art # A-08493

Input Power Cable Connections

Three-Phase (3ø)

Store copper jumpers on base plate

Single-Phase (1ø) and Jumper Settings

GND

L1

L2

L3
L4

GND

L1

L2

L3
L4

Single and Three Phase Input Power Wiring

NOTE

There are two jumpers used for the single phase 230V setting and none for three phase.

A. Connections to Single Phase Input Power

WARNING

Disconnect input power from the power supply and input cable before attempting this procedure.

These instructions are for changing the input power and or cable on the 208/230, 400, 460 VAC Power Supply to Single -

Phase input power.

1. Remove the Power Supply cover per instructions found in section 5.

2. Disconnect the original input power cable from the main input contactor and the chassis ground connection.

3. Loosen the through - hole protector on the back panel of the power supply. Pull the original power cable out of the

power supply.

4. If the power cable being used is not the factory - supplied cable, use a three - conductor input power cable for the volt-

age desired and strip back the insulation on the individual wires.

5. Pass the cable being used through the access opening in the back panel of the power supply. Refer to Section 2 for

power cable specifications.

CAUTION

The primary power source and power cable must conform to local electrical code and the recommended circuit

protection and wiring requirements (refer to table in Section 2).