Ultra-cut 400 – Tweco 400 Ultra-Cut User Manual
Page 88

OPERATION
4-14
Manual No. 0-5164
ULTRA-CUT 400
Fault Code Key
Error
Code
Error
Remedy / Comments
4-1
Coolant Level low
Check coolant level, add as needed.
4-2
Low coolant flow
Fault response time: Process Never started since last power cyle: Below 0.7 GPH
for 15 Seconds. Else below 0.5 GPH no delay or after 3 seconds if below 0.7
GPH Possible cause: Suction leak introducing air into coolant, suspect rear
panel filter seal; clogged filter; defective pump.
4-3
Coolant overheated
Coolant return temperature exceeded 70 degrees Celcius (158F). Coolant fan
failed; radiator fins clogged with dirt; operating with side panel loose or re-
moved. Ambient temperature > 40 deg C.
4-4
Coolant System not ready.
Proper coolant flow of 0.7 GPH was not obtained during up to 4 minutes of
Priming. New installation can require additional Priming cycle(s) to fill hoses
with coolant; cylce power to restart Priming; Suction leak introducing air into
coolant; suspect rear panel filter seal; Clogged coolant filter; Damaged torch
coolant tube; Defective pump assembly.
4-5
Low Coolant Level Warning Low coolant level during cut, does not stop cut.
Add coolant as required.
5-1
CANBUS Acknowledge
fault.
If GCM 1000, Basic ID signal missing; Other gas controls, Fiber disconnected
or broken, Transceiver (what fiber plugs into) fault, replace Gas control PCB or
CCM
5-2
CANBUS Off
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not locked
into connector; sharp bends in fiber; fiber defective;
5-3
CANBUS Errors Warning. Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not locked
into connector; sharp bends in fiber; fiber defective;
5-4
Reserved
No information available; Contact customer service
6-1
CCM Analog Voltage Error
Replace CCM
6-2
CCM ADC or DAC error
Replace CCM
6-3
Coolant Flow too High
Torch coolant tube broken or missing; CCM fault, replace CCM
6-4
CCM Data Memory error
Replace CCM
6-5
CCM Program memory fault Replace CCM
6-6
+5V Logic supply low
Replace CCM
6-7
CCM processor over temp
Reduce ambient tempurature; Defective CCM; replace
6-8
5V supply for RS 485/422
communication low.
Replace CCM