beautypg.com

Ultra-cut 400 – Tweco 400 Ultra-Cut User Manual

Page 88

background image

OPERATION

4-14

Manual No. 0-5164

ULTRA-CUT 400

Fault Code Key

Error

Code

Error

Remedy / Comments

4-1

Coolant Level low

Check coolant level, add as needed.

4-2

Low coolant flow

Fault response time: Process Never started since last power cyle: Below 0.7 GPH

for 15 Seconds. Else below 0.5 GPH no delay or after 3 seconds if below 0.7

GPH Possible cause: Suction leak introducing air into coolant, suspect rear

panel filter seal; clogged filter; defective pump.

4-3

Coolant overheated

Coolant return temperature exceeded 70 degrees Celcius (158F). Coolant fan

failed; radiator fins clogged with dirt; operating with side panel loose or re-

moved. Ambient temperature > 40 deg C.

4-4

Coolant System not ready.

Proper coolant flow of 0.7 GPH was not obtained during up to 4 minutes of

Priming. New installation can require additional Priming cycle(s) to fill hoses

with coolant; cylce power to restart Priming; Suction leak introducing air into

coolant; suspect rear panel filter seal; Clogged coolant filter; Damaged torch

coolant tube; Defective pump assembly.

4-5

Low Coolant Level Warning Low coolant level during cut, does not stop cut.

Add coolant as required.

5-1

CANBUS Acknowledge

fault.

If GCM 1000, Basic ID signal missing; Other gas controls, Fiber disconnected

or broken, Transceiver (what fiber plugs into) fault, replace Gas control PCB or

CCM

5-2

CANBUS Off

Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not locked

into connector; sharp bends in fiber; fiber defective;

5-3

CANBUS Errors Warning. Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not locked

into connector; sharp bends in fiber; fiber defective;

5-4

Reserved

No information available; Contact customer service

6-1

CCM Analog Voltage Error

Replace CCM

6-2

CCM ADC or DAC error

Replace CCM

6-3

Coolant Flow too High

Torch coolant tube broken or missing; CCM fault, replace CCM

6-4

CCM Data Memory error

Replace CCM

6-5

CCM Program memory fault Replace CCM

6-6

+5V Logic supply low

Replace CCM

6-7

CCM processor over temp

Reduce ambient tempurature; Defective CCM; replace

6-8

5V supply for RS 485/422

communication low.

Replace CCM