4-13 OPERATION

ULTRA-CUT 400

Fault Code Key

Error

Code

Error

Remedy / Comments

2-1

Missing AC Phase

Blown fuse, Broken or loose connection on power cable

2-2

Wrong input voltage

Inverter(s) not configured correctly for input voltage;

Poor power quality (brownouts, dropouts); Input power capacity / wiring

too small causing voltage drop; broken or loose power cable connec-

tions.

2-3

Inverter or Pilot Regulator Over

Temperature

2-4

Power Supply not Ready

2-5

DC Output Low

Less than 60 VDC; Defective inverter, shorted output; CCM voltage sense

(J6) wire open or disconnected. Negative lead short to gnd. Shorted

chopper (100-300A only).

2-6

Inverter input fault

Capacitor bank voltage imbalance (400-460-600V only) or inverter

primary switching circuit overcurrent. If occasional may be line voltage

surge; remove power to reset. If persists defective inverter; LED on

inverter indicate which one.

2-7

Unexpected current

Current above 20A in work or pilot leads before pilot ignition; Possible

shorted torch; Defective current sensor.

2-8

Unexpected current in pilot circuit

Current above 5A in pilot circuit; wrong or mismatched consumables;

Pilot lead shorted to negative in torch tube; Possible shorted torch

2-9

Unexpected current in work lead

Current above 5A in work lead; Short to chassis in RAS; Negative lead

short to ground.

2-10

Reserved

No information available; Contact customer service

2-11

Reserved

No information available; Contact customer service

3-1

Gas Control Communication fault. Cannot establish Communication with gas control. If Gas Control is

GCM 200 or (rest of text unchanged.)

3-2

Gas Control reply fault.

Connection was established but (rest of text unchanged.)

3-3

Gas Supply Pressure out of range.

If Gas Control is GCM 200 or GCM 1000 Plasma may be less than 51

PSI; faulty or disconnected pressure SW. If GCM

2010 is rev AG or GCM2000 is rev AC (or later) or Gas Control has been

updated with 19X2219_AG (or later) PCB then Plasma or Shield supply

pressure may be outside the range of 105-135 PSI.

Unplugged or faulty pressure sensor; faulty gas control PCB.

3-4

Gas Control not ready

Purging; Not in RUN mode; Gas Control faulty, replace PCB

3-5

Gas Control Protocol Error

Verify Firmware revison for compatiblity with CCM

3-6

Reserved

No information available; Contact customer service

3-7

Gas Control sequencing error

Verify Firmware revison for compatiblity with CCM

3-8

Gas Control Type Mismatch

CCM must be Ultracut type for GCM 2010; Autocut type for GCM 2000,

GCM 1000 or GCM 200

3-9

Gas Control Command fault

Verify Firmware revison for compatiblity with CCM

3-10

Reserved

No information available; Contact customer service

3-11

Reserved

No information available; Contact customer service

3-12

Reserved

No information available; Contact customer service

3-13

Reserved

No information available; Contact customer service