beautypg.com

Ultra-cut 400 – Tweco 400 Ultra-Cut User Manual

Page 41

background image

Manual No. 0-5164

3-15 INSTALLATION

ULTRA-CUT 400

2. Don’t hook onto the fiber to pull on the cable.

Art # A-09418

3. Once the fiber cable is installed in the CCM or gas control make sure the strain relief nut is securely tightened

onto the hose so the hose can’t pull out of it like this:

Art # A-09419

Sharp Bend

Hose not secured in

the Strain Relief

Correct installation:

Correct way to pull the cable is to use a snake or a wire or another cable and attach it securely to the hose behind the

strain relief. Then secure the fiber connector to the pulling device leaving some slack in the fiber. Keep the protective

end covers on the fiber until you are ready to connect it to the PCB in the CCM or gas control.

Art # A-09420