beautypg.com

Ultra-cut 400, Arc starter box, 18 install remote arc starter – Tweco 400 Ultra-Cut User Manual

Page 56

background image

INSTALLATION

3-30

Manual No. 0-5164

ULTRA-CUT 400

3.18 Install Remote Arc Starter

Site Location

Select a clean, dry location with good ventilation and adequate working space around all components.

Review the safety precautions in the front of this manual to be sure that the location meets all safety requirements.

Interconnecting cables and hoses attach to the Arc Starter. There must be adequate space around the Arc Starter
for these connections without excessive kinking or bending.

Mounting Dimensions

NOTE

Height not shown is 7.375” ( 187mm )

D.250”

3 PLACES

6.35mm

8.00”

203.20mm

12.00”

304.80mm

2.00”

50.80mm

1.49”

37.77mm

10.50”

266.70mm

7.51”

190.83mm

.50”

12.70mm

Arc Starter Box

Art # A-07961