CNC I/O Requirements for SC 3000 Electronic Enclosure
24 VDC
DISABLE
(9)
OK to MOVE (0 VDC or Contact)
24VDC COMM
(15)
OK to MOVE +
24 VDC
24 VDC
OK TO MOVE (20VDC or Contact)
OK to MOVE -
Plasma Start
Contact closure
or 20 VDC
(apply 24VDC)
(13)
PLASMA START (24 VDC)
24 VDC
(12)
(apply 24VDC)
24 VDC
(14)
J4 CNC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
(10)
(11)
Height Control Disable 24VDC
24 VDC
24 VDC
(16)
OK
SW1
SW1
2
1
3
5
4
6
+20 VDC
Art # A-09091
Plasma Start and Height Control Disable require +24 VDC to activate. If the CNC outputs can supply
+24V it can be used directly if it is referenced to the 24 VDC Common at J4-2.
If the CNC has relays with NO contacts the 24 VDC available from the SC 3000 at J4-1, 3 & 10 may
be routed through those relays to supply the required input signal.
For other CNC outputs such as single ended open collector user supplied relays will need to be added.
Art # A-09092
CNC OUTPUT
'
+
USER RELAY
'
VDC
Use DCV from CNC for relay coil or if using 24 VDC from SC3000
must also connect CNC common to SC 3000 24 VDC COMM
'
'
'
'
'
'
'
'
24 VDC @ J4-1
24 VDC @ J4-3 or J4-10
START (J4-4 ) or DISABLE (J4-11)
DIODE
24 VDC COMM @ J4-2
Reverse EMF protection
Diode required for DC relay
Single ended.