CUTMASTER A80, A120

Manual 0-5119

SERVICE

5-7

7. Remove the filter element assembly through

the rear opening.

NOTE

If replacing or cleaning just the filter element

refer to the following illustration for disassembly.

Art # A-07990

Filter Element

8. Install the new or cleaned assembly by revers-

ing these procedures.

9. Turn ON the air supply and check for leaks

before reinstalling the cover.

Optional Single-Stage Filter Element

Replacement

These instructions apply to power supplies where the

optional Single-Stage Filter has been installed.

The Power Supply shuts down automatically when

the Filter Element becomes completely saturated. The

Filter Element can be removed from its housing, dried,

and reused. Allow 24 hours for Element to dry. Refer

to Section 6, Parts List, for replacement filter element

catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down system

before disassembling Filter to change Filter

Element.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-

clockwise and remove it. The Filter Element

is located inside the Housing.

Art # A-02476

Filter

Element

(Cat. No. 9-7741)

Housing

Cover

Barbed

Fitting

Spring

Assembled Filter

O-ring

(Cat. No. 9-7743)

Optional Single-Stage Filter Element Replacement

5. Remove the Filter Element from the Housing

and set Element aside to dry.

6. Wipe inside of housing clean, then insert the

replacement Filter Element open side first.

7. Replace Housing on Cover.

8. Reattach gas supply.

NOTE

If unit leaks between housing and cover, inspect

the O-Ring for cuts or other damage.

Optional Two-Stage Filter Element

Replacement

The Two-Stage Air Filter has two Filter Elements.

When the Filter Elements become dirty the Power

Supply will continue to operate but cut quality may

become unacceptable. Refer to Section 6, Parts List,

for replacement filter element catalog number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

!

WARNING

Always turn OFF the air supply and bleed the

system before disassembling the Filter Assembly

as injury could result.

3. Loosen the two bolts on the top of the Filter

Assembly enough to allow the Filter Elements

to move freely.

4. Note the location and orientation of the old

Filter Elements.