beautypg.com

Mild steel 100a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 50

background image

CUTMASTER A80, A120

OPERATION Manual 0-5119

4T-18

Mild Steel
100A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8243

9-8218

9-8237

9-8212

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

75 (25')

75 (50')

110

0.18

85

0.20

0.10

0.09

3/8

0.375

112

0.18

75

0.20

0.20

0.09

1/2

0.500

115

0.18

45

0.20

0.40

0.10

5/8

0.625

118

0.18

30

0.20

0.60

0.11

3/4

0.750

120

0.18

20

0.20

1.20

0.12

1

1.000

123

0.18

15

Edge Start

0.12

1-1/4

1.250

128

0.18

8

Edge Start

0.13

Material

Thickness

Gas Pressure (Air) Arc Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6

5.2 (7.6 m)

5.2 (15.2 m)

110

4.6

2200

5.1

0.10

2.3

8

111

4.6

2030

5.1

0.10

2.3

10

112

4.6

1790

5.1

0.20

2.3

12

114

4.6

1310

5.1

0.40

2.5

15

117

4.6

870

5.1

0.60

2.7

20

120

4.6

490

5.0

1.20

3.0

25

123

4.6

390

Edge Start

3.0

30

127

4.6

250

Edge Start

3.2

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.