beautypg.com

Section 3 torch: installation, 3t.01 torch connections, 3t.02 cnc connection – Tweco A80-A120 CutMaster User Manual

Page 27: Section 3 torch, Installation t-1

background image

CUTMASTER A80, A120

Manual 0-5119

INSTALLATION

3T-1

SECTION 3 TORCH:

INSTALLATION

3T.01 Torch Connections

If necessary, connect the torch to the Power Supply.

Connect only the Thermal Dynamics model SL100SV

/ Automation, SL100 / Mechanical or SL100 / Manual

Torch to this power supply. Maximum torch leads

length is 100 feet / 30.5 m, including extensions.

WARNING

Disconnect primary power at the source before

connecting the torch.

1. Align the ATC male connector (on the torch

lead) with the female receptacle. Push the

male connector into the female receptacle. The

connectors should push together with a small

amount of pressure.

2. Secure the connection by turning the locking

nut clockwise until it clicks. DO NOT use the

locking nut to pull the connection together. Do

not use tools to secure the connection.

1

2

Art # A-07885

Connecting the Torch to the Power Supply

3. The system is now ready for operation.

Check Air Quality

To test the quality of air:

1. Put the ON / OFF

switch in the ON

(up) position.

2. Put the Function Control switch in the SET

position.

3. Place a welding filter lens in front of the torch

and turn ON the air.

Do not start an arc!

Any oil or moisture in the air will be visible on
the lens.

3T.02 CNC Connection

1. Locate the interface connection port on the rear

of the power supply.

Automation Interface
Cable Port

Art # A-08464

2. Note the pin-out of the connector and that the

customer supplied connector matches.

Art # A-08323

Plasma

Start / Stop

Signal

Cutting Machine

OK to Move

3. Connect CNC to the power supply.