Tweco 151 with SL100SV User Manual
Page 29
Manual 0-4691
3-5
INSTALLATION
3
B. Optional Air Filters
1. Connect the Filter as illustrated. Use only Synflex or equivalent grade hose. The illustrations show typical fittings
as an example.
NOTE
For a secure seal, apply thread sealant to the fitting threads, according to the maker's instructions. Do Not use
Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the torch.
Connect as follows:
Art # A-03000
Regulator/Filter
Assembly
Inlet Port
Bowl
1/4 NPT Hose Fitting
1/4" (6 mm) Gas Supply Hose
Hose Clamp
Art # A-03004
Regulator/Filter
Assembly
Hose
Clamp
1/4 NPT
Hose Fitting
1/4" (6 mm) Gas
Supply Hose)
2-Stage Filter
Inlet Port (IN)
Outlet Port
(OUT)
Regulator Inlet Port
Two Stage
Filter
Assembly
Optional Single-Stage Filter Installation Optional Two-Stage Filter Installation
C. Using High Pressure Air Cylinders
When using high pressure air cylinders as the air supply:
1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure regula-
tors.
2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly open
each cylinder valve to blow out any dust which may be present.
3. The cylinder must be equipped with an adjustable high-pressure regulator capable of outlet pressures up to 100 psi (6.9 bar)
maximum and flows of at least 500 scfh (236 lpm).
4. Connect supply hose to the cylinder.
NOTE
Pressure should be set at 100 psi (6.9 bar) at the high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do Not use
Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the torch.