beautypg.com

Tweco 150XL CE PAK Master Without Latch Circuit User Manual

Page 34

background image

OPERATION

4-8

Manual 0-2727

A-02288

Logic PC Board

SW3

1 2

Figure 4-8 Gas Pre-Flow Delay Switch SW3

Location

Select the proper gas pre-flow time for the total torch lead
length as shown in the following chart:

Gas Pre-Flow Delay Function

Pre-Flow

(Seconds)

Total Torch

Lead Length

SW3-1

SW3-2

2 *

0 - 60 ft

(0 - 18.3 m)

1 (ON)

1 (ON)

3.4

61 - 85 ft

(18.6 - 25.9 m)

1 (ON)

0 (OFF)

4

86 - 125 ft

(26.2 - 38.1 m)

0 (OFF)

0 (OFF)

* = Factory Setting