OPERATION

E. OK-To-Move Selection (SW5)

SW5

A-00995

Logic

PC Board

Figure 4-12 OK-To-Move Selection Switch SW5

Location

The OK-To-Move Selection Switch (SW5) selects ei-
ther contact closure or 24 VAC for the OK-To-Move
signal (motion start).

OK-To-Move Selection

SW5

Contact Closure *

UP

24 Vac

DOWN

* = Factory Setting

NOTE

Switch SW5 must be in the UP position when us-
ing Remote Control RC6010 or Standoff Control
SC11.

To use the contact closure for the OK-To-Move signal
the switch should be in the up position (factory set-
ting). To use 24 VAC for the OK-To-Move signal the
switch should be in the down position.

To get a motion start signal when starting off the edge
of the workpiece, not a pierce start, jumper TB2-8 to
TB2-9 and TB2-7 to TB2-10 to give an OK-To-Move
contact closure when the pilot starts via pilot sensing
relay (PSR). The switch, SW5, must be in the contact
closure (up) position or the 24 VAC will be shorted
out and blow the internal fuse (F3).

24VAC

J2-19

J2-18

J15-11

J15-10

SW5

OK-To-Move

J2-16

J2-14

Logic PCB

OK-To-Move

At Pilot

Initiation

PSR

TB2-10

TB2-9

TB2-8

TB2-7

A-01009

Figure 4-13 OK-To-Move Using PSR

An external voltage source up to 120V may be con-
nected in series with the Pilot Sensing Relay (PSR) or
OK-To-Move. This also works with the RC6010, re-
fer to RC6010 Manual for 24 VAC or external volt-
age. RC6010 must have only contact closure from
the Power Supply.

J15-11

J15-10

External Voltage

Source Alternate

Positions

OK

PSR

TB2-10

TB2-9

TB2-8

TB2-7

A-01010

Figure 4-14 OK-To-Move Using External Supply